Operating and Installation Instructions Ventilation Hood To prevent accidents and damage to the appliance, you must read these instructions before installing the appliance and using it for the first time. en-US M.-Nr.
Contents IMPORTANT SAFETY INSTRUCTIONS ................................................................ 4 Caring for the environment ................................................................................ 13 Guide to the appliance ........................................................................................ 14 Description of functions ..................................................................................... 16 Before using for the first time ..................................
Contents OdorFree Charcoal Filter ....................................................................................... 38 Resetting the filter saturation indicator for the charcoal filters......................... 39 Disposing of charcoal filters ............................................................................. 39 Service and warranty .......................................................................................... 40 Location of the data plate .......................................
IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage. Read all instructions before installing or using the appliance for the first time. Only use the appliance for its intended purpose. Keep these operating instructions in a safe place and pass them on to any future user. Appropriate use CAUTION: For General Ventilating Use Only.
IMPORTANT SAFETY INSTRUCTIONS Safety with children As with any appliance, close supervision is necessary when used by children. Please supervise children in the vicinity of the hood and do not let them play with it. The LED ClearView lighting is very intense. Ensure that especially babies/small children don't look into the light. Danger of suffocation! Ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of the reach of children.
IMPORTANT SAFETY INSTRUCTIONS Reliable and safe operation of this hood can only be guaranteed if it has been connected to the electrical supply. To avoid damaging the ventilation hood, make sure that the connection data (voltage and frequency) on the data plate correspond to the building's power supply before connecting the appliance. If in doubt, consult a qualified electrician. Do not use a power bar or extension cord to connect the ventilation hood to electricity.
IMPORTANT SAFETY INSTRUCTIONS During installation, maintenance, and repair work, the ventilation hood must be disconnected from the electrical supply. It is only completely isolated from the electricity supply if one of the following applies: – The circuit breakers on the electrical service panel are tripped. – The screw-type fuses on the electrical service panel have been removed. – The power cord (if present) has been unplugged from the socket (pull the plug not the cord).
IMPORTANT SAFETY INSTRUCTIONS Correct use WARNING: TO REDUCE THE RISK OF A COOKTOP GREASE FIRE: – a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers may ignite. Heat oils slowly on low or medium settings. – b) Always turn the hood on when cooking at a high heat. – c) Clean the ventilation hood frequently. Grease should not be allowed to accumulate on the fan or filter. – d) Use the proper pan size.
IMPORTANT SAFETY INSTRUCTIONS The ventilation hood may become damaged if exposed to excessive heat from a gas cooktop. – When using the ventilation hood over a gas cooktop, ensure that any burners in use are always covered by cookware. Turn burners off when removing the cookware, even if doing so for just a short time. – Select cookware that is suitable for the size of the burner. – Adjust the flame so that it never extends up the sides of the cookware. – Avoid overheating the cookware (e.g.
IMPORTANT SAFETY INSTRUCTIONS Proper installation WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: – a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. – b) Sufficient air is needed for combustion and exhausting of gases through the flue (chimney of fuel burning equipment to prevent back drafting.
IMPORTANT SAFETY INSTRUCTIONS Be sure to observe the information contained in the “Installation” section when mounting the ventilation hood. Metal parts can have sharp edges which may cause injury. Wear gloves to protect your hands from being cut. When installing the exhaust duct, only use pipes or tubes made of non-flammable material. These can be obtained from your Miele dealer or from Miele Technical Service.
IMPORTANT SAFETY INSTRUCTIONS FCC Declaration of Conformity These devices comply with FCC Rules Part 15. This equipment has been tested and found to be in compliance with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules of Operation and is subject to the following conditions: These devices may not cause harmful interference. These devices must accept any interference received, including interference that may cause undesired operation.
Caring for the environment Disposal of the packing material The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of the reach of children. Danger of suffocation! Disposal of your old appliance Electrical and electronic appliances contain valuable materials.
Guide to the appliance 14
Guide to the appliance a Exhaust connection Extraction ducting can be directed upward, to the rear, or to the left-hand side.
Description of functions The following functions are available on your ventilation hood, depending on the model: Extraction mode The cooking vapors are drawn in by the ventilation hood. The air is then passed via the edge extraction panel through the grease filters, cleaned and then directed outside. 16 Recirculation mode (DUU 2900-900 conversion kit required) The air is drawn in via the edge extraction panel and cleaned by the grease filters.
Before using for the first time Selecting extraction mode or recirculation mode The ventilation hood can be operated with either extraction mode or recirculation mode. The power of the blower is adapted to suit the selected mode of operation. The ventilation hood is set up at the factory for recirculation mode. It has to be reset for extraction mode. To reset it for extraction mode, the filter saturation indicator for the charcoal filter(s) has to be deactivated. Switch off the blower and the lighting.
Before using for the first time Connecting via the app Switch the ventilation hood off. The Miele@mobile app can be used to connect to your network. Install the Miele@mobile app on your mobile device. Press and hold the control. To log in you will need: 1. Your WiFi network password 2. Your ventilation hood password Press the lighting control at the same time. 2 will light up constantly, 3 will flash on and off. The ventilation hood is ready for connection in the next two minutes.
Before using for the first time Connecting via WPS Your WiFi router must support WPS (WiFi Protected Setup). Switch the ventilation hood off. Press and hold the control. Press the lighting control at the same time. Start the WiFi connection on your WiFi router. When successfully connected, 2 and 3 will light up constantly. Quit connection mode on the ventilation hood by pressing the delayed shutdown control . 2 will light up constantly, 3 will flash on and off.
Before using for the first time Signing out of WiFi (reset to factory settings) To set up a new WiFi connection, the existing WiFi connection must be disconnected. Touch the control. Switch the ventilation hood off. 2 will light up constantly, 3 will flash on and off. Press and hold the control. Touch the lighting control at the same time. With an existing WiFi connection, 2 and 3 will light up constantly. The ventilation hood is ready for disconnection during the next two minutes.
Before using for the first time Setting up Con@ctivity Con@ctivity is the direct communication system between an induction Miele cooktop and a Miele ventilation hood. It enables the ventilation hood to operate automatically depending on the operational state of a Miele cooktop with onset controls. Con@ctivity with direct wireless connection (Con@ctivity 2.0) Required: – Con@ctivity 2.0 enabled Miele induction cooktop – When a burner is turned on, the overhead lighting on the hood turns on automatically.
Before using for the first time Installing the Con@ctivity 2.0 stick Activating the ventilation hood See the relevant installation instructions provided with the Con@ctivity 2.0 stick. The cooktop and ventilation hood must be switched off. Activating the wireless connection The ventilation hood and the cooktop must be installed and operational. The wireless connection must be activated on the ventilation hood and the cooktop at the same time. Activation on the ventilation hood is described below.
Before using for the first time Finishing activation on the ventilation hood To activate Con@ctivity 2.0, press the control. When successfully connected, B will go out, and 2 and 3 will light up constantly. 2 will light up constantly, 3 will flash on and off. After a few seconds, 2 and 3 will light up constantly, B will flash on and off. The search for a wireless connection will start. Activating the cooktop While the ventilation hood is searching for a signal, start activating the cooktop.
Before using for the first time Activation failed If a wireless connection cannot be established despite activation of the Con@ctivity function on the ventilation hood and cooktop, the function must first be deactivated and then reactivated on both appliances. Deactivating the wireless connection Press the control to deactivate Con@ctivity 2.0. 2 will light up constantly, 3 will flash on and off. The cooktop and ventilation hood must be switched off.
Operation (Automatic mode) When Con@ctivity is active, the ventilation hood always operates in Automatic mode (see “Setting up Con@ctivity”). If you wish to manually operate the ventilation hood, see “Cooking without Con@ctivity”. Examples for power levels 1 to B Cooking with Con@ctivity (Automatic mode) Turn on a burner to the desired power setting. The overhead lighting will come on.
Operation (Automatic mode) Cooking process Switching off If, for example, you switch on a burner at the highest power setting to heat cookware in preparation for searing and then reduce the power level after approx. 10 seconds to 4 minutes, a cooking process is recognized. Turn off all burners. The hood turns on automatically and, after the cooktop power level has been reduced, switches back to blower level 3, where it remains for approx. 5 minutes.
Operation (Automatic mode) Temporarily exiting Automatic mode To temporarily exit Automatic mode when cooking: Manually select a different blower level, or Manually turn the hood off, or Activate the delayed shutdown function on the ventilation hood. The blower will switch itself off after the selected delayed shutdown time, and the lighting will remain on. You can also operate the ventilation hood manually for a complete cooking process.
Operation (Manual mode) Cooking without Con@ctivity (Manual mode) Selecting the delayed shutdown time The ventilation hood can be operated manually if: It is advisable to run the blower for a few minutes after cooking has finished. This helps to neutralize any lingering vapors and odors in the air. – The Con@ctivity function is not activated. – You have temporarily deactivated the Con@ctivity function (see “Temporarily exiting Automatic mode”).
Operation (Manual mode) Dimming/switching the overhead lighting on/off The overhead lighting can be switched on and off and dimmed independently of the blower. Press the lighting control briefly to switch it on or off. The lighting will switch on at maximum brightness. Power management The ventilation hood features a power management system to help save energy. The blower power level is reduced and the lighting is turned off automatically.
Operation (Manual mode) Turning power management on/off Safety shut-off Switch off the blower and the lighting. If power management has been deactivated, the ventilation hood will switch itself off automatically after 12 hours if it has been left on (blower and overhead lighting). Press the delayed shutdown control for approx. 10 seconds until the 1 indicator appears in the blower level display. Then press in turn: – the lighting control , – the control, and then – the lighting control .
Operation (Automatic and Manual modes) Filter saturation indicator Switch off the blower and the lighting. The ventilation hood registers the length of time it has been operated. Press the delayed shutdown control and the filter saturation control at the same time. The filter saturation indicators show when the filters need to be cleaned or changed by lighting up the grease filter symbol or charcoal filter symbol .
Operation (Automatic and Manual modes) Adjusting or deactivating the filter saturation indicator for the charcoal filters Checking the filter saturation indicator Charcoal filters are needed for recirculation mode. Before the set operating time has run out, you can check what percentage of the time has elapsed. You can set the filter saturation indicator to suit your cooking habits. Press the On/Off control to turn the blower on. It has to be deactivated for extraction mode.
Energy-saving tips This hood operates in a very efficient and energy-saving manner. The following will help you to save even more energy when using it: – Ensure that there is sufficient ventilation in the kitchen when cooking. If there is insufficient air flow during extraction mode, the hood cannot operate efficiently, causing increased operating noise levels. – Always cook with the lowest possible setting.
Cleaning and care WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before cleaning or servicing the hood, disconnect it from the power supply, see “IMPORTANT SAFETY INSTRUCTIONS”. Stainless steel housing General information The surfaces and control buttons are susceptible to scratching and chipping. Observe the following cleaning instructions. Clean all surfaces and control buttons using warm water and liquid dish soap. Apply with a sponge cloth.
Cleaning and care Important for the controls Do not leave dirt and debris on the buttons for any length of time. Otherwise they may become discolored or damaged. Remove any dirt or debris immediately. Observe the general cleaning instructions contained in this chapter. Do not use a stainless steel cleaner to clean the control buttons. Grease filters and edge extraction panel Risk of fire! Oversaturated grease filters are a fire hazard. Clean the grease filters at regular intervals.
Cleaning and care Removing the panel and grease filters The panel and grease filter can fall out when you are handling them. This can result in damage. Make sure you hold the panel and the grease filter securely at all times when handling them. Open the grease filter locking clamp and remove the grease filter. Cleaning the panel by hand Follow the instructions under “Housing.
Cleaning and care Unsuitable cleaning agents After cleaning Unsuitable cleaners can cause damage to the filter surfaces if used regularly. Do not use any of the following: After cleaning, leave the filters on an absorbent surface to dry.
Cleaning and care Resetting the filter saturation indicator for the grease filters Once cleaning is complete, the filter saturation indicator must be reset. While the blower is turned on, press the filter saturation indicator for approx. 3 seconds until 1 is the only indicator flashing. The grease filter symbol goes out. When cleaning the grease filters before the full operating time has elapsed: Press the filter saturation indicator for approx. 6 seconds until 1 is the only indicator flashing.
Cleaning and care Resetting the filter saturation indicator for the charcoal filters After changing the charcoal filters, the filter saturation indicator must be reset. To do this, press the filter saturation indicator twice with the blower turned on and hold it for approx. 3 seconds until 1 is the only indicator flashing. The charcoal filter symbol will go out.
Service and warranty For faults that you cannot resolve on your own, please contact your Miele dealer or Miele Technical Service. MieleCare The telephone number for Miele is listed at the back of these instructions. MieleCare, our Extended Service Contract program, gives you the assurance of knowing that your appliance investment is covered by 5 years of worry free ownership.
Installation Before installation Before installing the appliance, read all of the information contained in this chapter and also in the “IMPORTANT SAFETY INSTRUCTIONS” section. Installation Instructions Please refer to the accompanying installation sheet for instructions on how to install the appliance. Leave these instructions with the appliance for the consumer/user. Information is subject to change.
Installation Installation parts 42
Installation a 1 vent connection for exhaust ducting 6" (150 mm). Keep the following in a safe place: e ntag tallation aje gio nt Ins Mo Montag ntering agem s nt Mo Mo Asennu Mo b 1 reducing collar for exhaust ducting 5" (125 mm). c Miele DUU 2900-900 conversion kit for recirculation mode (not supplied, see “Technical data” for part number to order). 14 M4 x 8 mm screws to secure the ventilation hood. Installation plan 1 suction cup for taking the bulbs out.
Installation Appliance dimensions 44
Installation a Exhaust connection can be made on the top, left side and rear of the ventilation blower box. b The ventilation hood is fastened in the cut-out using clamps. A solid installation surface, e.g., made of wood, is required. Make sure that the structure can support the load. Around the clamps, components such as supports and ducting must be at least 1" (25 mm) from the cut-out. c There are additional fixing points on the installation surface.
Installation Installation recommendations – We recommend a minimum distance of 27 ⁹/₁₆" (700 mm) and a maximum distance of 51 ³/₁₆" (1,300 mm). – Please note that the greater the distance from the cooktop, the less effective the hood is at drawing in the cooking vapors. – To achieve optimum vapor extraction, the ventilation system must be centered over the cooktop, not to the side or behind. – The cooktop should be no wider than the hood. Preferably, it should be narrower for better extraction.
Air venting WARNING: Danger of toxic fumes. Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. To reduce the risk of fire and to properly exhaust air, the exhaust gases extracted by the hood should be vented outside of the building only. Do not vent exhaust air into spaces within walls or ceilings or in attics, crawl spaces or garages. To reduce the risk of fire, only use metal ductwork.
Air venting Reducing Collar (optional accessory) If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed. It reduces the air flow to less than 400 CFM. Check local building codes for max. CFM requirements. Push the Reducing Collar on the exhaust port of the blower. Push the exhaust hose over it. Secure both with a hose clamp.
Electrical connection WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: All electrical work should be performed by a qualified electrician in strict accordance with national regulations (for USA: ANSI-NFPA 70) and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. Ensure that power to the appliance is OFF while installation or repair work is performed.
Technical data Blower motor 350 W Overhead lighting 4x3W Total connected load Supply voltage, frequency 362 W 120 V AC, 60 Hz Fuse 15 A Power cord length 2.5 ft (0.75 m) Weight 46.2 lbs (21 kg) WiFi module Frequency band 2.412–2.462 GHz Maximum transmission power < 100 mW ZigBee® module Frequency band 2.405–2.48 GHz Maximum transmission power < 10 mW Optional accessories for recirculation mode DUU 2900-900 conversion kit and two DKF 18-900 charcoal filters.
Please have the model and serial number of your appliance available when contacting Technical Service. U.S.A. Canada Miele, Inc. Importer Miele Limited National Headquarters 9 Independence Way Princeton, NJ 08540 Phone: 800-843-7231 609-419-4298 Fax: www.mieleusa.com Technical Service & Support Phone: 800-999-1360 888-586-8056 Fax: TechnicalService@mieleusa.com International Headquarters Miele & Cie.
DA 2818 en-US M.-Nr.