17
Turning on the blower
Switch the blower on as soon as you
start cooking. This is to ensure that
vapors are captured right from the start.
Pull out the canopy. For optimum
extraction with minimum noise levels,
always pull the canopy out to its full
extent.
The blower turns on at level 2. The
symbol and 2 will light up in the blower
level display.
Selecting the power level
Power levels 1 to 3 are available for light
to heavy cooking vapors and odors.
For strong vapors and odors that are
temporarily produced when cooking,
e.g., during searing, select the B
Booster setting.
Select the power level you want by
pressing the or control.
Automatic Booster setting
switch-off
You have the option to program the
booster level to ensure the fan will
always switch back to level 3
automatically after 10minutes.
To set this option, both the blower
and the overhead lighting must be
turned off and the fume deflector
pushed in.
Press theandbuttons at the
same time for approx. 10 seconds,
until 1 lights up.
Then, press the following buttons in
succession:
- the lighting button,
- followed by the button and then
- the lighting buttonagain.
If automatic switch-off is not activated,
the 1 and B displays will flash.
To activate it, press thebutton.
If 1 and B are lit, automatic switch-off is
activated.
To deactivate it, press thebutton.
Use the On/Off buttonto confirm
your choice of setting.
If you do not confirm within
4minutes, the system will revert to
the old setting.