Operating and Installation Instructions Ventilation Hood To prevent accidents and damage to the appliance, you must read these instructions before installing the appliance and using it for the first time. en-US M.-Nr.
Contents IMPORTANT SAFETY INSTRUCTIONS ................................................................ 4 Caring for the environment ................................................................................ 13 Description of functions ..................................................................................... 14 Con@ctivity 2.0 function........................................................................................ 15 Guide to the appliance ..........................................
Contents Plywood backing .................................................................................................. 37 To install a plywood backing ................................................................................ 37 Exhaust duct ........................................................................................................ 38 Condensate trap.................................................................................................... 39 Reducing Collar ................
IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage. Read all instructions before installing or using the appliance for the first time. Only use the appliance for its intended purpose. Keep these operating instructions in a safe place and pass them on to any future user. Use CAUTION: For General Ventilating Use Only.
IMPORTANT SAFETY INSTRUCTIONS Children As with any appliance, close supervision is necessary when used by children. Please supervise children in the vicinity of the hood and do not let them play with it. Danger of suffocation! Ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of the reach of children.
IMPORTANT SAFETY INSTRUCTIONS Be certain your appliance is properly installed and grounded by a qualified technician. To guarantee the electrical safety of this appliance, continuity must exist between the appliance and an effective grounding system. It is imperative that this basic safety requirement be met. If there is any doubt, have the electrical system of the house checked by a qualified electrician.
IMPORTANT SAFETY INSTRUCTIONS If the power cord is damaged, it must only be replaced by a qualified service technician. During installation, maintenance, and repair work, the ventilation hood must be disconnected from the electrical supply. It is only completely isolated from the electricity supply if one of the following applies: – The circuit breakers on the electrical service panel are tripped. – The screw-type fuses on the electrical service panel have been removed.
IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING*: – a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. – b) NEVER PICK UP A FLAMING PAN - You may be burned. – c) DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.
IMPORTANT SAFETY INSTRUCTIONS Overheated oils and fats can ignite and set the ventilation hood on fire. When cooking with oils or fats, do not leave pots, pans or fryers unattended. Never leave an electric grill unattended when grilling. Fat and debris deposits impair the proper functioning of the ventilation hood. To ensure that cooking vapors are properly cleaned, never use the ventilation hood without the grease filters in place.
IMPORTANT SAFETY INSTRUCTIONS Proper installation WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: – a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. – b) Sufficient air is needed for combustion and exhausting of gases through the flue (chimney of fuel burning equipment to prevent back drafting.
IMPORTANT SAFETY INSTRUCTIONS Be sure to observe the information contained in the "Installation" section when mounting the ventilation hood. Metal parts can have sharp edges which may cause injury. Wear gloves to protect your hands from being cut. When installing the exhaust duct, only use pipes or tubes made of non-flammable material. These can be obtained from your Miele dealer or from Miele Technical Service.
IMPORTANT SAFETY INSTRUCTIONS FCC Declaration of Conformity These devices comply with FCC Rules Part 15. This equipment has been tested and found to be in compliance with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules of Operation and is subject to the following conditions: These devices may not cause harmful interference. These devices must accept any interference received, including interference that may cause undesired operation.
Caring for the environment Disposal of the packing material The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of the reach of children. Danger of suffocation! Disposal of your old appliance Do not dispose of this appliance with your household waste. Old appliances may contain materials that can be recycled.
Description of functions The following functions are available on your ventilation hood, depending on the model: Vented mode The air is drawn into the ventilation hood. It is then cleaned by the edge extraction panels and the grease filters and directed outside. Non-return flap A non-return flap in the ducting prevents the exchange of inside and outside air from occurring when the ventilation hood is not in use. The flap is closed when the ventilation hood is turned off.
Description of functions Con@ctivity 2.0 function Automatic control This hood features a communication function which enables the automatic control of the hood based on the operational status of a Miele induction cooktop. The cooktop transmits information about its operational status to the hood using a radio signal. – When a burner is turned on, the cooktop lighting on the hood turns on automatically. After a brief delay, the ventilation hood fan also comes on.
Guide to the appliance 16
Guide to the appliance a Telescopic chimney b Chimney c Canopy d Control panel e Grease filter f Edge extraction panels Optional accessories DRP 6590 W glass (3 elements) DRP 6590 W stainless steel (3 elements) DRP 6520 W glass (4 elements) DRP 6520 W stainless steel (4 elements) g Recirculation vent (only for recirculation mode) h Cooktop lighting i OdorFree Charcoal Filter Optional accessory for recirculation mode j Button for cooktop lighting k On/Off button for fan l Buttons for setting the fan power m
Operation (Automatic mode) When Con@ctivity 2.0 is active, the hood always operates in Automatic mode (see "Activating Con@ctivity 2.0"). See "Cooking without Con@ctivity 2.0" for information on manually operating the hood. Cooking with Con@ctivity 2.0 (Automatic mode) Turn on a burner to the desired power setting. Overhead cooktop lighting. After a few seconds, the fan will come on, briefly operating at power level 2 before immediately switching to level 1.
Operation (Automatic mode) Cooking process Deactivation If, for example, you switch on a burner at the highest power setting to heat cookware in preparation for searing and then reduce the power level after approx. 60 to 90 seconds, a cooking process is recognized. Turn off all burners. The hood turns on automatically and, after the cooktop power level has been reduced, switches back to fan level 3, where it remains for approx. 5 minutes.
Operation (Automatic mode) Temporarily exiting Automatic mode To temporarily exit the Automatic mode when cooking: Manually select a different fan level, or Manually turn the hood off, or Activate the Delayed shut down function on the ventilation hood. The fan turns off after the delay time selected, and the lighting will remain on. The ventilation hood functions can now be operated manually (see "Cooking without Con@ctivity 2.0").
Operation (Manual mode) Cooking without Con@ctivity 2.0 (Manual mode) Selecting the Delayed shut down time The hood can be operated manually if: It is a good idea to let the fan run for a few more minutes after cooking in order to neutralize any lingering vapors and odors in the air. With the Delayed shut down function, it is possible to have the fan automatically shut off after a predetermined period of time. – The Con@ctivity 2.0 function is not activated.
Operation (Manual mode) Power management The 1 and IS indicators will flash. The ventilation hood features a power management system to help save energy. The fan power level is reduced and the lighting is turned off automatically. To turn it on, press the "" button. – If the intensive setting is selected, the fan automatically switches to level 3 after 5 minutes.
Operation (Automatic and Manual modes) Filter saturation indicator The number of hours the hood has been in operation is stored in appliance memory. The filter saturation indicators show when the filters need to be cleaned or changed by lighting up the grease filter symbol or OdorFree Charcoal Filter symbol . Additional information on cleaning and changing the filters and resetting the filter saturation counters can be found under "Cleaning and care.
Operation (Automatic and Manual modes) Activating/changing the OdorFree Charcoal Filter saturation timer The OdorFree Charcoal Filter is required for recirculation mode. The filter saturation timer for the OdorFree Charcoal Filter requires onetime activation and must be set to match your cooking habits. Press the On/Off button to turn the fan off. Press the "" symbol and the filter saturation indicator at the same time.
Cleaning and care WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before cleaning or servicing the hood, disconnect it from the power supply, see "IMPORTANT SAFETY INSTRUCTIONS". Stainless steel housing General information The surfaces and control buttons are susceptible to scratching and chipping. Observe the following cleaning instructions. Clean all surfaces and control buttons using warm water and liquid dish soap. Apply with a sponge cloth.
Cleaning and care Important for the controls Do not leave dirt and debris on the buttons for any length of time. Otherwise they may become discolored or damaged. Remove any dirt or debris immediately. Observe the general cleaning instructions contained in this chapter. Do not use a stainless steel cleaner to clean the control buttons. Panels and grease filters for edge extraction The edge extraction panels and the reusable metal grease filters in the appliance remove solid particles (grease, dust, etc.
Cleaning and care Removing the panels and grease filters The grease filters and panels can fall out when you are handling them. This can result in damage. Make sure you hold the filters and panels securely at all times when handling them. Cleaning the panels by hand Follow the instructions under "Housing." Cleaning the grease filters by hand Clean the filters with a soft nylon brush in a mild solution of hot water and dish soap. Do not use undiluted dish soap.
Cleaning and care After cleaning After cleaning, leave the filters on an absorbent surface to dry. When removing the panels and grease filters for cleaning, also clean off any accessible oil or grease buildup from the housing. Doing so will prevent a fire hazard. Reinstall the grease filters. When inserting the filters, make sure that the locking clip is facing down. Resetting the filter saturation counter for the grease filters Once cleaning is complete, the filter saturation counter must be reset.
Cleaning and care OdorFree Charcoal Filter If the hood is equipped for recirculation, an OdorFree Charcoal Filter must be installed in addition to the grease filters. This filter is designed to absorb odorcausing agents and is mounted in the canopy above the grease filters. Installing/replacing the OdorFree Charcoal Filter To install or replace the OdorFree Charcoal Filter, the grease filters must first be removed as described above. Remove the OdorFree Charcoal Filter from its packaging.
Cleaning and care The OdorFree Charcoal Filter saturation counter requires one-time activation before use (see the "Operation" chapter). Resetting the filter saturation counter for the filter If the filter saturation counter is activated, it must be reset each time the filter is changed. To do this, press the filter saturation indicator twice with the fan turned on and hold it for approx. 3 seconds until 1 is the only indicator flashing. The OdorFree Charcoal Filter symbol will go out.
Installation Before installation Before installing the appliance, read all of the information contained in this chapter and also in the "IMPORTANT SAFETY INSTRUCTIONS" section. Removing the protective film Disassembly If the device ever needs to be disassembled, follow the installation sheet instructions in reverse order. A lever is provided to assist with the removal of the chimney. Unscrew the two mounting screws on the chimney.
Installation Installation parts 32
Installation a 3 protective installation sheets for use when installing the chimney b 1 exhaust connector for an exhaust duct 6" (150 mm). c 1 reducer for an exhaust duct 5" (125 mm). d 1 non-return flap for installation in the outlet duct collar of the motor unit (not for recirculation mode). Depending on the device version, the non-return flap is already mounted. e Telescopic wall bracket for securing the ventilation hood on the wall.
Installation Appliance dimensions The drawing is not to scale.
Installation c Air vent positioned at the top for recirculation de Installation area (only d is required for recirculation ventilation hoods). Wall and ceiling area for exhaust duct opening and for wall socket installation. Only the wall socket installation is required for recirculation hoods. Vent collar 6" (150 mm), with adapter 5" (125 mm).
Installation Installation recommendations – We also recommend a distance of at least 26" (660 mm) above electric cooktops to provide more workspace and easier cooking under the hood. Drilling diagram for wall mounting When drilling, please follow the directions contained on the accompanying installation sheet. – When selecting an installation height, always take the user height into consideration.
Installation Plywood backing The majority of the weight of the installed ventilation system will be supported by the lower retaining plate. It must be firmly attached to the stud framing behind the drywall. If studs are not available in the required locations, a plywood backing (min. ½" (13 mm) thick) spanning at least two studs must be installed. Failure to adequately support the weight as stated may result in the ventilation system falling off the wall, causing personal injury and property damage.
Exhaust duct WARNING: Danger of toxic fumes. Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. To reduce the risk of fire and to properly exhaust air, the exhaust gases extracted by the hood should be vented outside of the building only. Do not vent exhaust air into spaces within walls or ceilings or in attics, crawl spaces or garages. To reduce the risk of fire, only use metal ductwork.
Exhaust duct Condensate trap Reducing Collar (optional accessory) In addition to insulating the exhaust duct, we recommend installing a condensate trap to collect and evaporate any condensate which might accumulate. Condensate traps are available for exhaust ducts with a diameter of 5" (125 mm) or 6" (150 mm). When installing a condensate trap, make sure that it is positioned vertically and, if possible, directly above the hood outlet duct collar.
Electrical connection WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: All electrical work should be performed by a qualified electrician in strict accordance with national regulations (for USA: ANSI-NFPA 70) and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. Ensure that power to the appliance is OFF while installation or repair work is performed.
Activating Con@ctivity 2.0 Installation of the Con@ctivity 2.0 stick In order for you to be able to use the Con@ctivity 2.0 function, the cooktop must be equipped with a Con@ctivity 2.0 stick. See the relevant installation instructions of the Con@ctivity 2.0 stick. Activating the ventilation hood The cooktop and ventilation hood must be turned off. Press and hold the delayed shutdown button 515 for approx. 10 seconds until the 1 indicator appears in the fan level display.
Activating Con@ctivity 2.0 Activating the cooktop Activation failed While the ventilation hood is searching for a wireless connection, start activation on the cooktop. More information can be found in the operating instructions for the cooktop. If a wireless connection cannot be established despite activation of the Con@ctivity function on the ventilation hood and cooktop, the function must first be deactivated and then reactivated on both appliances.
Service and warranty For faults that you cannot resolve on your own, please contact your Miele dealer or Miele Technical Service. MieleCare The telephone number for Miele is listed at the back of these instructions. MieleCare, our Extended Service Contract program, gives you the assurance of knowing that your appliance investment is covered by 5 years of worry free ownership.
Technical data Fan motor Cooktop lighting Total connected load Voltage, Frequency Fuse rating Power cord length 350 W 3x3W 359 W 120 V AC, 60 Hz 15 A 2.5 ft (0.75 m) Weight DA 6596 W 55 lbs (25 kg) DA 6526 W 61.6 lbs (28 kg) Optional accessories for recirculation mode: Recirculation kit DUW 20 and OdorFree Charcoal Filter DKF 12 Contains FCC ID: 2ACUWEI8800 IC: 5669C-EI8800 This device complies with Part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s).
Please have the model and serial number of your appliance available before contacting Technical Service. U.S.A. Canada Miele, Inc. Importer Miele Limited National Headquarters 9 Independence Way Princeton, NJ 08540 Phone: 800-843-7231 609-419-4298 Fax: www.mieleusa.com Technical Service & Support Nationwide Phone: 800-999-1360 888-586-8056 Fax: TechnicalService@mieleusa.com International Headquarters Miele & Cie.
DA 6596 W DA 6526 W en-US M.-Nr.