Operating and Installation Instructions Ventilation Hood To prevent accidents and damage to the appliance, you must read these instructions before installing the appliance and using it for the first time. en-US M.-Nr.
Contents IMPORTANT SAFETY INSTRUCTIONS ............................................................ 4 Caring for the environment .............................................................................. 13 Guide to the ventilation hood ........................................................................... 14 Description of functions ................................................................................... 16 Before using for the first time ..............................................
Contents Grease filters ....................................................................................................... OdorFree Charcoal Filter ..................................................................................... Resetting the filter saturation indicator for the charcoal filters....................... Disposing of charcoal filters ........................................................................... 35 37 37 37 Installation...................................................
IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage. Read all instructions before installing or using the appliance for the first time. Only use the appliance for its intended purpose. Keep these operating instructions in a safe place and pass them on to any future user. Appropriate use CAUTION: For General Ventilating Use Only.
IMPORTANT SAFETY INSTRUCTIONS Safety with children Children must be kept away from the ventilation hood unless they are constantly supervised. Please supervise children in the vicinity of the hood and do not let them play with it. The LED ClearView lighting is very intense. Ensure that especially babies/small children don't look into the light. Danger of suffocation.
IMPORTANT SAFETY INSTRUCTIONS Be certain your appliance is properly installed and grounded by a qualified technician. To guarantee the electrical safety of this appliance, continuity must exist between the appliance and an effective grounding system. It is imperative that this basic safety requirement be met. If there is any doubt, have the electrical system of the house checked by a qualified electrician.
IMPORTANT SAFETY INSTRUCTIONS Defective components should be replaced by Miele original parts only. Only with these parts can safety of the appliance be assured as intended by the manufacturer. If the power cord is damaged, it must only be replaced by a qualified service technician. During installation, maintenance, and repair work, the ventilation hood must be disconnected from the electrical supply.
IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING*: - a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. - b) NEVER PICK UP A FLAMING PAN - You may be burned. - c) DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.
IMPORTANT SAFETY INSTRUCTIONS Overheated oil and fat can ignite, causing fire damage to the ventilation hood. Do not leave cookware, pans, and deep-fat fryers unattended when cooking with oil or fat. Similarly, never leave an open flame unattended when grilling. Fat and debris deposits impair the proper functioning of the ventilation hood. To ensure that cooking vapors are properly cleaned, never use the ventilation hood without the grease filters in place.
IMPORTANT SAFETY INSTRUCTIONS Proper installation WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: - a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. - b) Sufficient air is needed for combustion and exhausting of gases through the flue (chimney of fuel burning equipment to prevent back drafting.
IMPORTANT SAFETY INSTRUCTIONS Be sure to observe the information contained in the “Installation” section when mounting the ventilation hood. Components can have sharp edges which may cause injury. Wear gloves to protect your hands. When installing the exhaust duct, only use pipes or tubes made of non-flammable material. These can be obtained from your Miele dealer or from Miele Technical Service.
IMPORTANT SAFETY INSTRUCTIONS FCC Declaration of Conformity These devices comply with FCC Rules Part 15. This equipment has been tested and found to be in compliance with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules of Operation and is subject to the following conditions: These devices may not cause harmful interference. These devices must accept any interference received, including interference that may cause undesired operation.
Caring for the environment Disposal of the packing material The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of the reach of children. Danger of suffocation! Disposal of your old appliance Electrical and electronic appliances contain valuable materials.
Guide to the ventilation hood 14
Guide to the ventilation hood a Telescopic extension piece b Duct cover c Canopy d Controls e Grease filter f Recirculation vents Only for recirculation mode g Overhead lighting h Charcoal filters Optional accessories for recirculation mode i Sensor control for turning the blower on and off j Sensor control for switching the lighting on and off and for dimming the lighting k Sensor controls for setting the blower power l Sensor control for the delayed shutdown function m Sensor control for the grease filter
Description of functions The following functions are available on your ventilation hood, depending on the model: Extraction mode The air is drawn in and cleaned by the grease filters and directed outside. 16 Recirculation mode The recirculation mode requires a recirculation kit and OdorFree Charcoal Filter (available as optional accessories, see “Technical Data” for more information) The air is drawn in and first cleaned by the grease filters and then by an OdorFree Charcoal Filter.
Before using for the first time Selecting extraction mode or recirculation mode The ventilation hood can be operated with either extraction mode or recirculation mode. The power of the blower is adapted to suit the selected mode of operation. The ventilation hood is set up at the factory for recirculation mode. It has to be reset for extraction mode. To reset it for extraction mode, the filter saturation indicator for the charcoal filter(s) has to be deactivated. Switch off the blower and the lighting.
Before using for the first time Connecting via the app Switch the ventilation hood off. The Miele app can be used to connect to your network. Install the Miele app on your mobile device. Press and hold the B control. To log in you will need: 1. your WiFi network password 2. your ventilation hood password Touch the lighting control at the same time. 2 will light up constantly, 3 will flash on and off. The ventilation hood will be ready for connection in the next 2 minutes.
Before using for the first time Connecting via WPS Your WiFi router must support WPS (WiFi Protected Setup). Switch the ventilation hood off. Press and hold the B control. Touch the lighting control at the same time. Start the WiFi connection on your WiFi router. When successfully connected, 2 and 3 will light up constantly. Quit connection mode on the ventilation hood by touching the delayed shutdown control . 2 will light up constantly, 3 will flash on and off.
Before using for the first time Signing out of WiFi (reset to factory settings) To set up a new WiFi connection, the existing WiFi connection must be disconnected. Touch the 1 control. Switch the ventilation hood off. 2 will light up constantly, 3 will flash on and off. Press and hold the 1 control. Touch the lighting control at the same time. With an existing WiFi connection, 2 and 3 will light up constantly. The ventilation hood is ready for disconnection during the next two minutes.
Before using for the first time Setting up Con@ctivity Con@ctivity is the direct communication system between an induction Miele cooktop and a Miele ventilation hood. It enables the ventilation hood to operate automatically depending on the operational state of a Miele cooktop with onset controls. Con@ctivity with direct wireless connection (Con@ctivity 2.0) Required: - Con@ctivity 2.0 enabled Miele induction cooktop - When a burner is turned on, the overhead lighting on the hood turns on automatically.
Before using for the first time Installing the Con@ctivity 2.0 stick Activating the ventilation hood See the relevant installation instructions provided with the Con@ctivity 2.0 stick. The cooktop and ventilation hood must be switched off. Activating the wireless connection The ventilation hood and the cooktop must be installed and operational. The wireless connection must be activated on the ventilation hood and the cooktop at the same time. Activation on the ventilation hood is described below.
Before using for the first time Finishing activation on the ventilation hood Touch the B control to activate Con@ctivity 2.0. When successfully connected, B will go out, and 2 and 3 will light up constantly. 2 will light up constantly, 3 will flash on and off. After a few seconds, 2 and 3 will light up constantly, B will flash on and off. The search for a wireless connection will start. Activating the cooktop While the ventilation hood is searching for a signal, start activating the cooktop.
Before using for the first time Activation failed If a wireless connection cannot be established despite activation of the Con@ctivity function on the ventilation hood and cooktop, the function must first be deactivated and then reactivated on both appliances. Deactivating the wireless connection Touch the 1 control to deactivate Con@ctivity 2.0. 2 will light up constantly, 3 will flash on and off. The cooktop and ventilation hood must be switched off.
Operation (Automatic mode) When Con@ctivity is active, the ventilation hood always operates in automatic mode (see “Before using for the first time – Setting up Con@ctivity”). If you wish to operate the ventilation hood manually; see “Operation (Manual mode) – Cooking without Con@ctivity”. Examples for power levels 1 to B Reaction time Cooking with Con@ctivity (Automatic mode) Turn on a burner to the desired power setting. The overhead lighting will come on.
Operation (Automatic mode) Cooking process Switching off For example, you switch on a burner at the highest power level to heat cookware for frying. After approx. 10 seconds to 4 minutes, you then reduce the power level (60 seconds to 5 minutes for a HiLight cooktop). Turn off all burners. The ventilation hood recognizes a cooking process.
Operation (Automatic mode) Temporarily exiting Automatic mode To temporarily exit Automatic mode when cooking: Manually select a different blower level; or Manually turn the ventilation hood off; or Activate the delayed shutdown function on the ventilation hood. The blower will switch itself off after the selected run-on time, and the lighting will remain on. You can also operate the ventilation hood manually for a complete cooking process.
Operation (Manual mode) Cooking without Con@ctivity (Manual mode) Selecting the delayed shutdown time The ventilation hood can be operated manually if: It is advisable to run the blower for a few minutes after cooking has finished. This helps to neutralize any lingering vapors and odors in the air. - The Con@ctivity function is not activated. - You have temporarily deactivated the Con@ctivity function (see “Operation (Automatic mode) – Temporarily exiting Automatic mode”).
Operation (Manual mode) Dimming/switching the overhead lighting on/off The overhead lighting can be switched on and off and dimmed independently of the blower. Touch the lighting control briefly to switch it on or off. The lighting will switch on at maximum brightness. With the lighting switched on, press and hold the lighting control . The brightness will gradually dim until you release the control.
Operation (Manual mode) Activating/deactivating power management Switch off the blower and the lighting. Touch the delayed shutdown control for approx. 10 seconds, until 1 lights up in the power level display. Then press in order: - the lighting control , - the 1 control, and then - the lighting control . When power management is turned on, the 1 and B indicators will be continuously lit. When it is turned off, the 1 and B indicators will flash.
Operation (Automatic and Manual modes) Filter saturation indicator Switch off the blower and the lighting. The ventilation hood registers the length of time it has been operated. Touch the delayed shutdown control and the grease filter control at the same time. The filter saturation indicators show when the filters need to be cleaned or changed by lighting up the grease filter symbol or charcoal filter symbol .
Operation (Automatic and Manual modes) Adjusting or deactivating the filter saturation indicator for the charcoal filter Checking the filter saturation indicator The charcoal filter is needed for recirculation mode. Before the set operating time has run out, you can check what percentage of the time has elapsed. The filter saturation indicator can be set to suit the customer’s cooking habits. Press the On/Off control to turn the blower on. It has to be deactivated for vented mode.
Energy-saving tips This hood operates in a very efficient and energy-saving manner. The following will help you to save even more energy when using it: - Ensure that there is sufficient ventilation in the kitchen when cooking. If there is insufficient air flow during extraction mode, the hood cannot operate efficiently, causing increased operating noise levels. - Always cook with the lowest possible setting.
Cleaning and care Before proceeding with any maintenance or cleaning task, the ventilation hood must be disconnected from the power supply, see “IMPORTANT SAFETY INSTRUCTIONS”. Stainless steel housing General information The surfaces and control buttons are susceptible to scratching and chipping. Observe the following cleaning instructions. Clean all surfaces and control buttons using warm water and liquid dish soap. Apply with a sponge cloth. After cleaning, dry the surfaces with a soft cloth.
Cleaning and care Grease filters Risk of fire Oversaturated grease filters are a fire hazard. Clean the grease filters at regular intervals. Removing the grease filters When handling the grease filter, be careful not to drop it. This can result in damage to the filter and the cooktop below. Make sure you hold the filter securely at all times when handling it. The re-usable metal grease filters in the appliance remove solid particles (grease, dust, etc.
Cleaning and care Unsuitable cleaning agents Unsuitable cleaners can cause damage to the filter surfaces if used regularly. Do not use any of the following: - Lime removers - Abrasive powders or abrasive liquids - Aggressive all-purpose cleaners and degreaser sprays - Oven sprays Cleaning the grease filters in a dishwasher Place the grease filters upright or slightly inclined in the lower basket. Ensure the spray arm is not obstructed. Use a commonly available household dishwashing detergent.
Cleaning and care OdorFree Charcoal Filter With recirculation mode, a charcoal filter must be fitted in addition to the grease filters. The charcoal filter is designed to absorb cooking odors. The charcoal filter is fitted in the canopy above the grease filters. How to install/replace a charcoal filter Remove the grease filters before fitting or replacing a charcoal filter. Take the charcoal filter out of its packaging.
*INSTALLATION* Installation Before installation Before installation, it is important to read the information contained in this chapter and in the “IMPORTANT SAFETY INSTRUCTIONS” chapter. Removing the protective film The housing components are covered by a protective film to prevent them from damage during transport. Please remove this film before installing the housing components. It can be peeled off easily without any additional tools.
*INSTALLATION* DUW20 Installation Conversion kit for recirculation mode The conversion kit contains an exhaust grille, hose, and hose clips (not supplied, but available as an optional accessory. See “Technical data”).
*INSTALLATION* Installation Appliance dimensions The drawing is not to scale a Extraction mode b Recirculation 40
*INSTALLATION* Installation c Air vent positioned at the top for recirculation de Installation area (only d is required for recirculation operation). Wall or ceiling area for the ducting cutout and for the electrical outlet. For recirculation operation, only an electrical outlet needs to be installed.
*INSTALLATION* Installation Installation recommendations - A distance of at least 26" (660 mm) is recommended above electric cooktops to provide more workspace and easier cooking under the hood. Drilling diagram for wall mounting Please follow the directions given in the installation instructions supplied for drilling. - When selecting an installation height, always take the user height into consideration.
*INSTALLATION* Installation Plywood backing The majority of the weight of the installed ventilation system will be supported by the lower retaining plate. It must be firmly attached to the stud framing behind the drywall. If studs are not available in the required locations, a plywood backing (min. ½" (13 mm) thick) spanning at least two studs must be installed.
*INSTALLATION* Installation Air venting WARNING: Danger of toxic fumes. Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. To reduce the risk of fire and to properly exhaust air, the exhaust gases extracted by the hood should be vented outside of the building only. Do not vent exhaust air into spaces within walls or ceilings or in attics, crawl spaces or garages. To reduce the risk of fire, only use metal ductwork.
*INSTALLATION* Installation If the on-site vent system does not have a non-return flap, you can purchase one as an optional accessory. Condensate If the ducting is to run through cool rooms or ceiling space, for example, the significant variations in temperature between the different areas can cause condensate to form. Insulate the ducting to reduce temperature variations. If the ducting is to be laid horizontally, it must be laid with a downwards sloping gradient of at least ³/₈" (1 cm) per meter.
*INSTALLATION* Installation Electrical connection WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: All electrical work should be performed by a qualified electrician in strict accordance with national regulations (for USA: ANSI-NFPA 70) and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. Ensure that power to the appliance is OFF while installation or repair work is performed.
Customer Service Contact in the event of a fault In the event of a fault which you cannot remedy yourself, please contact your Miele dealer or Miele Customer Service. You can book a Miele Service Call online at www.miele.com/service. Contact information for Miele Customer Service can be found at the end of this document. Please quote the model identifier and serial number of your appliance (SN) when contacting Miele Customer Service. Both pieces of information can be found on the data plate.
Technical data Blower motor Overhead lighting Total connected load Supply voltage, frequency Fuse Power cord length Weight 350 W 3x3W 359 W 120 V AC, 60 Hz 15 A 2.5 ft (0.75 m) 57.2 lbs (26 kg) WiFi module Frequency range Maximum transmission power 2.400–2.4835 GHz < 100 mW ZigBee® module Frequency band Maximum transmission power 2.405–2.
Please have the model and serial number of your appliance available when contacting Customer Service. U.S.A. Canada Miele, Inc. Importer Miele Limited National Headquarters 9 Independence Way Princeton, NJ 08540 Phone: 800-843-7231 609-419-4298 Fax: www.mieleusa.com Customer Service & Support Phone: 888-99-MIELE(64353) 888-586-8056 Fax: service@mieleusa.com International Headquarters Miele & Cie.
DA 6698 W en-US M.-Nr.