Operating and Installation Instructions Ventilation Hood To prevent accidents and damage to the appliance, you must read these instructions before installing the appliance and using it for the first time. en-US M.-Nr.
Contents IMPORTANT SAFETY INSTRUCTIONS ............................................................ 4 Caring for the environment .............................................................................. 13 Guide to the ventilation hood ........................................................................... 14 Description of functions ................................................................................... 16 Before using for the first time ..............................................
Contents Appliance warranty and product registration ...................................................... 33 Installation.......................................................................................................... Before installation................................................................................................ Installation recommendations ............................................................................. Installation materials.....................................
IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage. Read all instructions before installing or using the appliance for the first time. Only use the appliance for its intended purpose. Keep these operating instructions in a safe place and pass them on to any future user. Appropriate use CAUTION: For General Ventilating Use Only.
IMPORTANT SAFETY INSTRUCTIONS Safety with children Children must be kept away from the ventilation hood unless they are constantly supervised. Children must not be allowed to clean or service the hood. Please supervise children in the vicinity of the hood and do not let them play with it. The LED ClearView lighting is very intense. Avoid looking directly into the light for prolonged periods of time. Danger of suffocation! Ensure that any plastic wrappings, bags, etc.
IMPORTANT SAFETY INSTRUCTIONS Technical safety WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: - Use this appliance only in the manner intended by the manufacturer. If you have questions, contact Miele. - Before servicing or cleaning the appliance, switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally.
IMPORTANT SAFETY INSTRUCTIONS Do not use a power bar or extension cord to connect the ventilation hood to electricity. These are a fire hazard and do not guarantee the required level of appliance safety. To ensure safe operation, only use the ventilation hood after it has been properly installed. This ventilation hood may not be used in non-stationary locations (e.g. on a ship).
IMPORTANT SAFETY INSTRUCTIONS Correct use WARNING: TO REDUCE THE RISK OF A COOKTOP GREASE FIRE: - a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers may ignite. Heat oils slowly on low or medium settings. - b) Always turn the hood on when cooking at a high heat. - c) Clean the ventilation hood frequently. Grease should not be allowed to accumulate on the fan or filter. - d) Use the proper pan size.
IMPORTANT SAFETY INSTRUCTIONS The ventilation hood may become damaged if exposed to excessive heat from a gas cooktop. - When using the ventilation hood over a gas cooktop, ensure that any burners in use are always covered by cookware. Turn burners off when removing the cookware, even if doing so for just a short time. - Select cookware that is suitable for the size of the burner. - Adjust the flame so that it never extends up the sides of the cookware. - Avoid overheating the cookware (e.g.
IMPORTANT SAFETY INSTRUCTIONS Proper installation WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: - a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. - b) Sufficient air is needed for combustion and exhausting of gases through the flue (chimney of fuel burning equipment to prevent back drafting.
IMPORTANT SAFETY INSTRUCTIONS The information provided in “Installation” must be observed when installing the ventilation hood. Components can have sharp edges which may cause injury. Wear gloves to protect your hands. When installing the exhaust duct, only use pipes or tubes made of non-flammable material. These can be obtained from your Miele dealer or from Miele Technical Service. Always observe local building code requirements when selecting duct material.
IMPORTANT SAFETY INSTRUCTIONS Accessories and parts Use only genuine original Miele parts. If parts or accessories from other manufacturers are used, the warranty may become void. Defective components should be replaced by Miele original parts only. Only with these parts can safety of the appliance be assured as intended by the manufacturer. Miele will guarantee to supply functional parts for a minimum of 10 years and up to 15 years following the discontinuation of your ventilation unit.
Caring for the environment Disposal of the packing material The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of the reach of children. Danger of suffocation! Disposal of your old appliance Electrical and electronic appliances contain valuable materials.
Guide to the ventilation hood 14
Guide to the ventilation hood a Pull-out canopy b Grease filter c Controls d Overhead lighting e Vent collar f Charcoal filters Optional accessories for recirculation mode g Sensor control for switching the ventilation hood on and off h Sensor controls for switching the blower on and off and for setting the blower power level i Sensor control for the delayed shutdown function j Sensor control for the grease filter saturation indicator k Sensor control for the charcoal filter saturation indicator l Sensor co
Description of functions The following functions are available on your ventilation hood, depending on the model: Extraction mode The air is drawn in and cleaned by the grease filters and directed outside. 16 Recirculation mode Recirculation mode hoods require a recirculation kit and OdorFree Charcoal Filters (available as optional accessories), see “Technical Data” for more information. The air is drawn in and cleaned first by the grease filters and then by the charcoal filters.
Before using for the first time Selecting vented mode or recirculation mode The ventilation hood can be operated with either vented mode or recirculation mode. The power of the blower is adapted to suit the selected mode of operation. The ventilation hood is set up at the factory for recirculation mode. The ventilation hood has to be reset for vented mode. To reset it for vented mode, the filter saturation indicator for the charcoal filter(s) has to be deactivated. Pull out the deflector plate.
Before using for the first time Miele@home availability To log in you will need: The ability to use the Miele app depends on the availability of the Miele@home service in your country. 1. your WiFi network password 2. your ventilation hood password The Miele@home service is not available in every country. For information about availability, please visit www.miele.com. Miele App The Miele App is available to download free of charge from the Apple App ® Store or from the Google Play Store™.
Before using for the first time Touch the On/Off switch . All symbols light up with reduced brightness. Connecting via WPS Your WiFi router must support WPS (WiFi Protected Setup). Touch the On/Off switch . Press and hold the delayed shutdown control until the grease filter and charcoal filter symbols light up. Touch the 2 control. 2 will light up constantly, 3 will flash on and off. The ventilation hood will be ready for connection in the next 2 minutes.
Before using for the first time Signing out of WiFi (reset to factory settings) Start the WiFi connection on your WiFi router. To set up a new WiFi connection, the existing WiFi connection must be disconnected. Touch the On/Off switch . When successfully connected, 2 and 3 will light up constantly. Exit connection mode on the ventilation hood by touching the delayed shutdown control . All symbols light up with reduced brightness.
Before using for the first time Touch the 1 control. 2 will light up constantly, 3 will flash on and off. After a few seconds, 2 and 3 will flash on and off. The connection has now been disconnected. Exit disconnection mode on the ventilation hood by touching the delayed shutdown control . The WiFi connection has now been disconnected. A new connection can now be set up.
Operation Turning on the fan Selecting the power level Switch the fan on as soon as you start cooking. This is to ensure that vapors are captured right from the start. Power levels 1 to 3 are available for light to heavy cooking vapors and odors. For strong vapors and odors that are temporarily produced when cooking, e.g., during searing, select the B booster level. Select the power level required by tapping a button from 1 to B. Selecting the second booster level Pull out the canopy.
Operation Selecting the delayed shutdown time Dimming/switching the cooktop lighting on/off It is advisable to run the blower for a few minutes after cooking has finished. This helps to neutralize any lingering vapors and odors in the air. You can switch the cooktop lighting on by pulling the deflector plate out and off by pushing it in. It also reduces the risk of residues accumulating in the ventilation hood and any resultant odors.
Changing settings All settings are made with the ventilation hood switched off. Pull out the deflector plate and switch off the blower and the lighting. Adjusting the grease filter filter saturation indicator Touch the On/Off switch . All symbols light up with reduced brightness. Press and hold the delayed shutdown control until the grease filter and charcoal filter symbols light up. The filter saturation indicator can be set to suit the customer’s cooking habits.
Changing settings Adjusting or deactivating the filter saturation indicator for the charcoal filter Charcoal filters are needed for recirculation mode. The filter saturation indicator can be set to suit the customer’s cooking habits. Deactivating power management Keep in mind that this may increase energy consumption. Activating/deactivating power management Touch the On/Off switch . It has to be deactivated for extraction mode. All symbols light up with reduced brightness.
Changing settings All the indicator lights will go out. If you do not confirm the new setting within 4 minutes, the ventilation hood will revert to the previous setting. Audible signal for the sensor controls When a function is selected with the sensor controls, a short audible signal will sound for confirmation. The audible signal can be switched off. Touch the On/Off switch . All symbols light up with reduced brightness.
Energy-saving tips This hood operates in a very efficient and energy-saving manner. The following will help you to save even more energy when using it: - Ensure that there is sufficient ventilation in the kitchen when cooking. If there is insufficient air flow during extraction mode, the hood cannot operate efficiently, causing increased operating noise levels. - Always cook with the lowest possible setting.
Cleaning and care Before proceeding with any maintenance or cleaning task, the ventilation hood must be disconnected from the power supply, see “IMPORTANT SAFETY INSTRUCTIONS”. Stainless steel housing General information The surfaces and control buttons are susceptible to scratching and chipping. Observe the following cleaning instructions. Clean all surfaces and control buttons using warm water and liquid dish soap. Apply with a sponge cloth. After cleaning, dry the surfaces with a soft cloth.
Cleaning and care Grease filters Risk of fire Oversaturated grease filters are a fire hazard. Clean the grease filters at regular intervals. Removing the grease filters When handling the grease filter, be careful not to drop it. This can result in damage to the filter and the cooktop below. Make sure you hold the filter securely at all times when handling it. The re-usable metal grease filters in the appliance remove solid particles (grease, dust, etc.
Cleaning and care Cleaning the grease filters in a dishwasher Resetting the filter saturation indicator for the grease filter Place the grease filters upright or slightly inclined in the lower basket. Ensure the spray arm is not obstructed. Once cleaning is complete, the filter saturation indicator must be reset. Use a commonly available household dishwashing detergent. In a Miele dishwasher use the “Normal” program.
Cleaning and care OdorFree Charcoal Filter With recirculation mode, two charcoal filters must be fitted in addition to the grease filters. These are designed to absorb cooking odors. When to change the OdorFree Charcoal Filter Replace the charcoal filters when they no longer absorb kitchen odors effectively, and at least every 6 months. Charcoal filters are available to order via the Miele Web Store (see end of this booklet for contact details), or from your Miele dealer.
Cleaning and care Reactivatable charcoal filters Reactivatable charcoal filters are available for this ventilation hood. They can be used several times after being reactivated in the oven. Please follow the operating instructions supplied with the filters. Open the tab using a tool such as a screwdriver. Take hold of the tab to pull the charcoal filter out. Insert the charcoal filters into the slots as far as they will go. Replace the lid.
Customer Service Contact in the event of a fault In the event of a fault which you cannot remedy yourself, please contact your Miele dealer or Miele Customer Service. You can book a Miele Service Call online at www.miele.com/service. Contact information for Miele Customer Service can be found at the end of this document. Please quote the model identifier and serial number of your appliance (SN) when contacting Miele Customer Service. Both pieces of information can be found on the data plate.
*INSTALLATION* Installation Before installation Installation materials Before installation, it is important to read the information contained in this chapter and in the “IMPORTANT SAFETY INSTRUCTIONS” chapter. Information is subject to change. Please refer to our website to obtain the most current product specification, technical & warranty information. 1 non-return flap for fitting into the exhaust socket on the motor unit (not needed for recirculation mode).
*INSTALLATION* Installation Further installation materials (optional accessories) 6 screws, 4 x 15 mm 4 M4 x 16 mm screws Mo e ntag tallation aje gio nt Ins Mo Montag ntering agem s nt Mo Mo Asennu Installation plan See the installation plan for details of the individual steps involved in the installation of this appliance. Leave these instructions with the appliance for the consumer/user.
*INSTALLATION* Installation Appliance dimensions DAS 8930 in a 35 ⁷/₁₆" (900 mm) wide cabinet. The drawing is not to scale a The mounting brackets are designed for cabinets with sides that are between ⁵/₈" and ³/₄" (16 and 19 mm) thick. b The ducting can also be connected at the back. c Cut-out for vented mode or recirculation mode with DUU 150 conversion kit d The upper cabinet can be fitted with a partition after installation.
*INSTALLATION* Installation Distance between cooktop and ventilation hood (S) Provided a larger distance is not given by the manufacturer of the cooktop, follow the minimum safety distances between a cooktop and the bottom of the hood. Please also observe the information contained in the “IMPORTANT SAFETY INSTRUCTIONS” section.
*INSTALLATION* Installation Adjusting the deflector plate When retracted, the deflector plate is held in place by magnets. The retaining force of the magnets can be adjusted. The magnets should be adjusted such that the deflector plate is held in place securely on the left and right-hand side and can be lowered slightly. Adjust both sides equally. Turn in stages by a half turn each time and check the adjustment by lowering and raising the deflector plate.
*INSTALLATION* Installation - If the ducting has flaps, these must be opened whenever the ventilation hood is switched on. Any constriction of the air throughput will reduce extraction performance and increase operating noise. Ventilation stack Condensate If the ducting is to run through cool rooms or ceiling space, for example, the significant variations in temperature between the different areas can cause condensate to form. Insulate the ducting to reduce temperature variations.
*INSTALLATION* Installation Miele will not accept warranty claims for any functional defects or damage caused by inadequate ducting. Reducing Collar (optional accessory) If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed. It reduces the air flow to less than 400 CFM. Check local building codes for max. CFM requirements. Push the Reducing Collar on the exhaust port of the blower. Push the exhaust hose over it.
*INSTALLATION* Installation Grounding Instructions WARNING - Improper grounding can result in a risk of electric shock. This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing a path of least resistance. This appliance is equipped with a cord having a grounding wire with a grounding plug. If there is any doubt, have the electrical system of the house checked by a qualified electrician. Do not use an extension cord.
Technical data Blower motor Overhead lighting Total rated load Supply voltage, frequency Fuse rating Power-cord length Weight 350 W 3W 353 W 120 V AC, 60 Hz 15 A 2.5 ft (0.75 m) 44.1 lbs (20 kg) WiFi module Frequency range Maximum transmission power 2.400–2.4835 GHz < 100 mW Optional accessories for recirculation mode For recirculation mode, installation kit DUU 150 or DUU 151 and charcoal filters DKF 31-900 P or DFK 31-R (reactivatable) must be purchased as optional accessories.
Please have the model and serial number of your appliance available when contacting Customer Service. U.S.A. Canada Miele, Inc. Importer Miele Limited National Headquarters 9 Independence Way Princeton, NJ 08540 www.mieleusa.com Customer Support Phone: 888-99-MIELE (64353) info@mieleusa.com International Headquarters Miele & Cie. KG Carl-Miele-Straße 29 33332 Gütersloh Germany Headquarters and Miele Centre 161 Four Valley Drive Vaughan, ON L4K 4V8 www.miele.
DAS 8930 en-US M.-Nr.