Operation Manual

Altering the recommended
temperature permanently
Each function is allocated a specific re
-
commended temperature.
It is, however, possible to permanently
alter these pre-set temperatures, but
only within the range of temperatures
available for that particular function
(see the chart below).
Please ensure that the function selector
is at "0".
Function Function
number
Recom-
mended
tempera-
ture
set
ex-works
in °C
Tempera-
ture range
avail-
able
in °C
Q 2 100 80-100
P 3 95 80-100
N 4 55 50-60
Q1 5 100 90-100
_ 6 75 70-95
;G 7 100 90-100
Bio 8 75 70-80
Procedure:
^
Press and hold the - button.
^
Select DESCALE k with the function
selector.
4 1 will appear in the display.
^
Press the z/g button.
1002 will appear in the display.
The flashing figures in the first three po-
sitions show the temperature, 100 °C in
the above example. The figure in the
fourth position, the number 2 in the ex-
ample, shows the number of the corre-
sponding function (see the chart).
^ To alter the recommended tempera-
ture for this function press - or +, e.g.
to set 80 °C for COOK Universal
Q.
^
Press the z/g, button to move to the
next function, e.g. No. 3 in the chart
and alter its temperature as descri
-
bed above.
Use