Operation Manual

^
Attach a new valve insert t to the
blunt end of the special tool.
^
Insert this into the opening in the con
-
necting valve.
Make sure that sealing ring on the valve
insert is at the front.
^ Press the valve insert firmly into posi-
tion using the blunt end of the tool.
To change the rubber pad u on the
water container:
^
Pull the old rubber pad out of the
connecting valve.
^
Dampen the new rubber pad with
water.
^
Push the new rubber pad into the
connecting valve so that the extensi
-
on piece on the rubber pad sticks out
through the opening in the water con
-
tainer.
^
Using tweezers or pointed pliers pull
the extension piece through the ope
-
ning so that the small thicker end sits
in the inside of the water container.
To change the O-Ring v on the water
container:
^
Lay the water container on its side.
^
Use a finger nail, knife or a small
screwdriver to to get underneath the
O-Ring.
^
Pull the old O-Ring off.
^ Push the new O-Ring onto the con-
necting valve. Then lubricate it with
the silicone grease supplied (see
"O-Ring" in "Cleaning and Care").
Cleaning and care
51