Contents Safety instructions for installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installation notes - important! . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 DGC 5080 XL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Appliance and building-in dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Installation in a tall unit . . . . . . . . . . . . .
Safety instructions for installation The appliance must be installed by a suitably qualified and competent person in strict accordance with current national and local safety regulations. ~ Before installation, check the appliance for visible signs of damage. ~ Before connecting the appliance, make sure that the connection data on the data plate (voltage and frequency) match the mains electricity supply. Consult a qualified electrician if in any doubt.
Installation notes - important! Front dimensions 4
Installation notes - important! Room for the control panel to open and shut The area in front of the control panel must not be blocked by anything (such as a door handle) that would hinder the control panel from opening and shutting.
DGC 5080 XL Appliance and building-in dimensions Installation in a tall unit a Steam combi oven b Building-in niche c Inlet for mains connection cable to the appliance d Recommended position for electrical socket.
DGC 5080 XL Cut-outs for venting the steam combi oven To ensure that the steam combi oven has adequate ventilation, the following cut-outs measuring 500 x 40 mm must be made: a in the top of the housing unit b in the interim shelf above the building-in niche The furniture housing unit must not have a back panel fitted behind the building-in niche.
DGC 5080 XL Installation in a base unit If the steam combi oven is being installed underneath a hob, please follow the instructions for building in the hob and also take the building-in height for the hob into account. a Steam combi oven b Building-in niche c Inlet for mains connection cable to the appliance d Recommended position for electrical socket.
DGC 5080 XL Cut-outs for venting the steam combi oven To ensure that the steam combi oven has adequate ventilation, the following cut-outs measuring 500 x 40 mm must be made: a in the base of the building-in niche b in the floor of the cupboard space below the building-in niche The furniture housing unit must not have a back panel fitted behind the building-in niche.
DGC 5080 XL Installation in a tall unit in combination with an oven a Steam combi oven b Building-in niche c Inlet for mains connection cable to the appliance d Recommended position for electrical sockets.
DGC 5080 XL Cut-outs for venting the steam combi oven To ensure that the steam combi oven has adequate ventilation, the following cut-outs measuring 500 x 40 mm must be made: a in the top of the housing unit b in the interim shelf above the building-in niche The furniture housing unit must not have a back panel fitted behind the building-in niche. Cut-out for venting the oven: Please refer to the installation instructions for the oven.
DGC 5080 XL Installation in a tall unit in combination with EGW/ESW 50x0-14 a Steam combi oven b Building-in niche c Inlet for mains connection cable to the appliance d Recommended position for electrical sockets.
DGC 5080 XL Cut-outs for venting the steam combi oven To ensure that the steam combi oven has adequate ventilation, the following cut-outs measuring 500 x 40 mm must be made: a in the top of the housing unit b in the interim shelf above the building-in niche The furniture housing unit must not have a back panel fitted behind the building-in niche.
DGC 5080 XL Installation in a tall unit in combination with ESW 50x0-29 a Steam combi oven b Building-in niche c Inlet for mains connection cable to the appliance d Recommended position for electrical sockets.
DGC 5080 XL Cut-outs for venting the steam combi oven To ensure that the steam combi oven has adequate ventilation, the following cut-outs measuring 500 x 40 mm must be made: a in the top of the housing unit b in the interim shelf above the building-in niche The furniture housing unit must not have a back panel fitted behind the building-in niche.
DGC 5080 XL Installing the appliance ^ Push the appliance into the recess and align it. The appliance must be positioned level, with a maximum tolerance of 2°, to allow the steam generator to operate correctly. ^ Secure the appliance by screwing the two wood screws 3.5 x 25 mm (supplied) into the vertical strips on either side of the appliance (see illustration).
DGC 5085 XL Plumbing in the appliance a Stopcock b Inlet hose, L = 1500 mm c Drain hose, L = 3000 mm d The top end of the drain hose must not be higher than 500 mm where it connects to the odour trap. e Important: If an oven is being installed underneath the steam combi oven, the inlet and drain hose for the steam oven must not be positioned behind the oven in shaded area e.
DGC 5085 XL Appliance and building-in dimensions Installation in a tall unit a Steam combi oven b Building-in niche c Inlet for mains connection cable to the appliance d Recommended position for electrical socket.
DGC 5085 XL Cut-outs for venting the steam combi oven and for installing the water hoses To accommodate the water hoses and to ensure that the steam combi oven has adequate ventilation, the following cut-outs measuring 500 x 40 mm must be made: a in the top of the housing unit (for ventilation) b in the interim shelf above the building-in niche (for ventilation) c in the base of the building-in niche (for the water hoses) d in the floor of the housing unit (for the water hoses) The furniture housing unit m
DGC 5085 XL Installation in a base unit If the steam combi oven is being installed underneath a hob, please follow the instructions for building in the hob and also take the building-in height for the hob into account. a Steam combi oven b Building-in niche c Inlet for mains connection cable to the appliance d Recommended position for electrical socket.
DGC 5085 XL Cut-outs for venting the steam combi oven and for installing the water hoses To accommodate the water hoses and to ensure that the steam combi oven has adequate ventilation, the following cut-outs measuring 500 x 40 mm must be made: a in the base of the building-in niche b in the floor of the cupboard space below the building-in niche The furniture housing unit must not have a back panel fitted behind the building-in niche.
DGC 5085 XL Installation in a tall unit in combination with an oven a Steam combi oven b Building-in niche c Inlet for mains connection cable to the appliance d Recommended position for electrical sockets.
DGC 5085 XL Cut-outs for venting the steam combi oven and for installing the water hoses To accommodate the water hoses and to ensure that the steam combi oven has adequate ventilation, the following cut-outs measuring 500 x 40 mm must be made: a in the top of the housing unit (for ventilation) b in the interim shelf above the building-in niche for the steam combi oven (for ventilation) c in the base of the building-in niche (for the water hoses) d in the base of the building-in niche for the oven (for the
DGC 5085 XL Installation in a tall unit in combination with EGW/ESW 50x0-14 a Steam combi oven b Building-in niche c Inlet for mains connection cable to the appliance d Recommended position for electrical sockets.
DGC 5085 XL Cut-outs for venting the steam combi oven and for installing the water hoses To accommodate the water hoses and to ensure that the steam combi oven has adequate ventilation, the following cut-outs measuring 500 x 40 mm must be made: a in the top of the housing unit (for ventilation) b in the interim shelf above the building-in niche (for ventilation) c in the base of the building-in niche (for the water hoses) d in the floor of the housing unit (for the water hoses) The furniture housing unit m
DGC 5085 XL Installation in a tall unit in combination with ESW 50x0-29 a Steam combi oven b Building-in niche c Inlet for mains connection cable to the appliance d Recommended position for electrical sockets.
DGC 5085 XL Cut-outs for venting the steam combi oven and for installing the water hoses To accommodate the water hoses and to ensure that the steam combi oven has adequate ventilation, the following cut-outs measuring 500 x 40 mm must be made: a in the top of the housing unit (for ventilation) b in the interim shelf above the building-in niche (for ventilation) c in the base of the building-in niche (for the water hoses) d in the floor of the housing unit (for the water hoses) The furniture housing unit m
DGC 5085 XL Preparing the appliance Before installing and connecting the appliance, please read the section "Plumbing in the appliance". Fitting the inlet hose The water inlet hose connection is located on the top left-hand side on the back of the appliance. ^ Attach the connecting nut of the stainless steel hose to the screw thread. Make sure that it has been screwed on tightly. Fitting the drain hose The water drain hose connection is located on the bottom left-hand side on the back of the appliance.
DGC 5085 XL ^ Secure the appliance by screwing the two wood screws 3.5 x 25 mm (supplied) into the vertical strips on either side of the appliance (see illustration). ^ Connect the appliance to the water supply and drainage outlet. ^ Plug in the appliance and switch it on. ^ Using the Operating Instructions as a guide, check all oven functions are working correctly.
DGC 5085 XL Plumbed in water supply The inlet and drain hoses must be fitted in such a way that the appliance can be easily taken out of the housing unit by a service technician should repair work ever be necessary. Before installation, check the water hoses for visible signs of damage. Water hose data Stainless steel inlet hose length 1,500 mm (1.5m) C 12.5 mm C Connection to stopcock / connection to appliance each 33.5 mm Plastic drain hose length 3,000 mm (3.0 m) C 12.
DGC 5085 XL All items used for connecting the appliance to the mains water supply must comply with the current national and local safety regulations in the country where the appliance is being installed. The appliance is only suitable for connection to the cold water supply. This appliance is constructed to comply with German water regulations (DVGW), and may be connected to a suitable supply without an extra non-return valve if national regulations permit.
DGC 5085 XL Connection to the water inlet Before plumbing the appliance in, ensure that it is disconnected from the mains electricity supply. ^ Switch off at the mains. ^ Connect the stainless steel hose to the stopcock. Ensure that it is screwed into position correctly. The connection points are subject to mains water pressure. Turn on the stopcock slowly and check for leaks. Correct the position of the seal and union if appropriate.
Electrical connection All electrical work should be carried out by a suitably qualified and competent person, in strict accordance with current local and national safety regulations (BS 7671 in the UK). Installation, repairs and other work by unqualified persons could be dangerous. The manufacturer cannot be held liable for unauthorised work. Ensure power is not supplied to the appliance until after installation work has been carried out. The appliance must only be operated when built-in.
Electrical connection Important U.K. This appliance is supplied for connection to a single phase 230 V 50 Hz supply with a 3-core cable.
Energy efficiency class This appliance is rated energy efficiency class A in accordance with EN 50304. Tests were carried out using "Cake plus".