Operating and Installation Instructions Ventilation System To prevent accidents and machine damage, read these instructions before installation or use. en - US, CA M.-Nr.
Installation Instructions Read these instructions and the "Important Safety Instructions" before installing this ventilation system. The installation steps are described in the enclosed "Installation Diagram". Leave these instructions with the appliance for the consumer/user. Information is subject to change. Please refer to our website to obtain the most current product specification, technical & warranty information.
Caring for the environment Disposal of packing material Disposal of an old appliance The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Please recycle. Old appliances may contain materials that can be recycled. Please contact your local recycling center about the possibility of recycling these materials. ,DANGER Ensure that any plastic wrappings, bags, etc.
Appliance dimensions 19
Appliance dimensions 20
Appliance dimensions a The hood with exhaust collar is only used in air extraction mode with an internal or external blower. b Installation area; Wall/ceiling area respectively for vent hole and outlet installation. For recirculation mode only the outlet installation is required.
Appliance dimensions a The hood with exhaust collar is only used in air extraction mode with an internal or external blower. b Installation area; Wall/ceiling area respectively for vent hole and outlet installation. For recirculation mode only the outlet installation is required.
Appliance dimensions a Installation area; Wall/ceiling area respectively for vent hole and outlet installation.
Appliance dimensions Distance between cooktop and hood (S) Do not install this exhaust hood over cooktops burning solid fuel. Observe the cooktop manufacturer's instructions when determining the distance between cooktop and lower edge of the hood. Unless the instructions require a greater distance, the adjacent minimum safety distances apply for Miele cooktops. – If several gas surfaces are installed under the hood, the total output must be considered when determining the minimum safety distance.
Appliance dimensions Distance between cooktop and hood (S) Miele Range hood Internal / External blowers DAR 1120, DAR 1220 (30") DRIB/DREB XL (700 cfm) DAR 1130, DAR 1230 (36") DRIB/DREB XL (700 cfm) DRIB/DREB XXL (1100 cfm) Miele Electric Cooktops 24" (610 mm) Miele Electric Barbeques and Fryers 26" (660 mm) Miele Multiburner Gas cooktops < 43,000 BTU/hr (12.6 KW) and no burner >18,800 BTU/hr (5.5 KW) 26" (660 mm) Miele Multiburner Gas cooktops > 43,000 BTU/hr (12.
Plywood backing The majority of the weight of the installed ventilation system will be supported by the retaining plate. It must be firmly attached to the stud framing behind the drywall. If studs are not available in the required locations, a plywood backing (min. ½" (13 mm) thick) spanning at least two studs must be installed. Failure to adequately support the weight as stated may result in the ventilation system falling off the wall, causing personal injury and property damage.
Installation Before installation read the information in the "Dimensions" and "Important Safety Instruction" chapters. Under certain conditions, there is a danger of poisonous fumes by when the ventilation system and a furnace drawing interior air run at the same time. Installation instructions The individual installation steps are described in the included Installation diagram. Protective film (stainless steel units) The casing is covered with a protective film to prevent scratching during transport.
Air extraction ,WARNING Danger of toxic fumes. Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. To reduce the risk of fire and to properly exhaust air, the exhaust gases extracted by the hood should be vented outside of the building only. Do not vent exhaust air into spaces within walls or ceilings or in attics, crawl spaces or garages. To reduce the risk of fire, only use metal ductwork.
Air extraction – If the exhaust is ducted into an inactive flue, the air must be expelled parallel to the flow direction of the flue. Never connect an exhaust hood to an active chimney, dryer vent, flue, or room venting ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent flue. Important If the ductwork runs through rooms, ceilings, garages, etc. where temperature variations exist, it may need to be insulated to reduce condensation.
Electrical connection ,WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: All electrical work should be performed by a qualified electrician in strict accordance with national regulations (for USA: ANSI-NFPA 70) and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. Ensure that power to the appliance is OFF while installation or repair work is performed.
Technical data Total connected load Weight DAR 1120, DAR 1220 with DRIB XL or DREB XL . . . . . . 619 W DAR 1120 with DRIB XL . . . . . . . 59.6 lbs (27.1 kg) DAR 1130, DAR 1230 with DRIB XL or DREB XL . . . . . . 621 W DAR 1220 with DRIB XL . . . . . . . 83.8 lbs (38.1 kg) DAR 1130, DAR 1230 with DRIB XXL or DREB XXL . . . . 806 W DAR 1130 with DRIB XL . . . . . . . 66.2 lbs (30.1 kg) DAR 1130 with DRIB XXL . . . . . . 66.7 lbs (30.3 kg) DAR 1150, DAR 1250 with DRIB XXL or DREB XXL . . . .
32
33
34
35
DAR 1120, 1130, 1150 DAR 1220, 1230, 1250 en - US, CA M.-Nr.