Operating and Installation Instructions Built-in Vacuum Drawer To prevent accidents and machine damage, read these instructions before installation or use. en-US M.-Nr.
Contents IMPORTANT SAFETY INSTRUCTIONS ............................................................ 4 Caring for the environment .............................................................................. 14 Overview............................................................................................................. EVS 7010............................................................................................................. EVS 7670.......................................................
Contents Installation dimensions EVS 7010 ....................................................................... Installation in a tall or base unit...................................................................... Combination with an H 2840 or CVA/DGC/H 7x4x ........................................ Combination with a DGC/H 7x6x ................................................................... Side view ..................................................................................................
IMPORTANT SAFETY INSTRUCTIONS Please note that the vacuum-sealing drawer is referred to as the drawer in these operating instructions. This drawer complies with all current local and national safety requirements. Inappropriate use can, however, lead to personal injury and material damage. Read the operating and installation instructions carefully before using the drawer. They contain important information on safety, installation, use, and maintenance.
IMPORTANT SAFETY INSTRUCTIONS Appropriate use This drawer is intended for domestic use and use in other similar environments. The drawer is not intended for outdoor use. The drawer is only for domestic use to vacuum and seal food in vacuum bags intended for this purpose and to vacuum-seal food in vacuum-proof containers made of plastic or stainless steel. All other types of use are not permitted. Never vacuum-seal live food (e.g., mussels, seafood).
IMPORTANT SAFETY INSTRUCTIONS Safety with children Do not leave children unattended: Children should not be alone or unsupervised in the area where the appliance is installed. Do not allow them to sit or stand on the appliance. Be sure to supervise any children in the vicinity of the drawer, and do not let them play with it. The sealing bar becomes hot during operation. The weld seam of the vacuum bag is also heated to a very high temperature during the sealing process.
IMPORTANT SAFETY INSTRUCTIONS Technical safety Proper installation: Make sure that your appliance has been installed correctly and that it has been grounded by a qualified technician. Maintenance by the user: Never repair or replace any part of the appliance unless the instructions specifically recommend doing so. Service work should only be performed by a qualified technician. Unauthorized installation, maintenance, and repairs can cause considerable danger for the user.
IMPORTANT SAFETY INSTRUCTIONS Temporary or permanent operation on an autonomous power supply system or a power supply system that is not synchronized with the grid power supply (e.g., island networks, back-up systems) is possible. A prerequisite for operation is that the power supply system complies with the specifications of EN 50160 or an equivalent standard.
IMPORTANT SAFETY INSTRUCTIONS Any contact with live connections or tampering with the electrical or mechanical components of the drawer will endanger your safety and may lead to appliance malfunctions. Do not open the casing of the drawer under any circumstances. Do not operate the drawer with wet hands or if you are in contact with water. Any repairs not performed by a Miele authorized service technician will void the warranty.
IMPORTANT SAFETY INSTRUCTIONS If the drawer is installed behind a cabinet panel (e.g., a door), ensure that the door is never closed while the drawer is in use. Heat and moisture can build up behind a closed cabinet panel and cause subsequent damage to the drawer, the housing unit, and the floor. Do not close the door until the sealing bar and the drawer have cooled down completely.
IMPORTANT SAFETY INSTRUCTIONS Correct use Storage in the appliance: Flammable materials should not be stored in the drawer. Danger of burning. The sealing bar gets hot during operation. The weld seam of the vacuum-sealing bag is also heated to a very high temperature during the sealing process. Do not touch the sealing bar or the weld seam immediately after the vacuum-sealing process. Risk of fire. Do not store any easily flammable substances and materials in the vicinity of the drawer.
IMPORTANT SAFETY INSTRUCTIONS Moisture in food or drinks can cause corrosion damage in the drawer. Do not use the drawer to store food or drinks. Miele does not permit vacuum-sealing of glass containers. Never insert the tubes attached to the drawer into any body orifices. Vacuum sealing single-use jars and jars with twist-off lids in the closed vacuum chamber: Risk of injury. Damage and cracks in jars or glass/twist-off lids can cause implosion.
IMPORTANT SAFETY INSTRUCTIONS Cleaning and maintenance Danger of electric shock. The steam from a steam cleaner could reach live electrical components and cause a short circuit. Never use a steam cleaner for cleaning.
Caring for the environment Disposal of the packing material The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of the reach of children. Danger of suffocation! Disposal of your old appliance Electrical and electronic appliances contain valuable materials.
Overview EVS 7010 a Air filter cover (see “Installation”) b Glass lid with chamber seal Push down on the little black triangle to close the glass lid. c Sealing bar in the vacuum chamber and counterpressure bar on the inside of the glass lid d Drawer front with Push2open mechanism The drawer can be opened and closed by lightly pressing the drawer front.
Overview EVS 7670 a Air filter cover (see “Installation”) b Glass lid with chamber seal Push down on the little black triangle to close the glass lid. c Sealing bar in the vacuum chamber and counterpressure bar on the inside of the glass lid d Drawer front with Push2open mechanism The drawer can be opened and closed by lightly pressing the drawer front.
Overview Controls and indicators Sensor buttons Displays/Indicator lights a On/Off sensor control For switching the drawer on and off h indicator light Indicates a warning (see “Problem solving guide”) b Vaccum sensor control For setting the vacuum setting c Seal sensor control For setting the sealing level/sealing the bag early d Container sensor control For setting the vacuum setting for external containers i Segment bar indicator lights For displaying the: – vacuum setting – sealing level – vac
Overview Included accessories The accessories supplied with your appliance, as well as a range of optional ones, are available to order from Miele (see “Optional accessories”).
Cleaning for the first time Remove any protective foil and stickers. Cleaning the drawer for the first time Do not remove stickers carrying safety or installation information or the data plate. Take all accessories out of the drawer. This makes it easier to perform servicing and repair work. Damage due to unsuitable cleaning agents. The glass lid and the chamber seal become damaged or scratched. Do not clean with any abrasive or acidic cleaning agents or sharp pointed objects.
Operation Storage compartment (EVS 7670 only) Risk of damage due to overloading. Overloading the storage compartment will damage the telescopic runners. Only load the storage compartment with maximum 33 lb (15 kg). Opening the storage compartment Open the drawer. Reach behind the recess in the front of the vacuum-sealing compartment from below and push the vacuumsealing compartment back completely. Closing the storage compartment Close the drawer.
Operation Suitable vacuum-sealing bags Only vacuum-sealing bags meeting the following material requirements are permitted for use: Important usage information Miele does not permit vacuum sealing of glass containers. - suitable for use with food - Only vacuum seal food. - suitable for freezing and cooking - Only use food that is fresh and in good condition.
Operation - If you want to vacuum seal several types of food in one bag, place the food evenly side-by-side in the bag. - Fill the vacuum-sealing bag to a maximum of ²/₃ with solid food or ¹/₃ with liquid. - For a perfect weld seam, make sure that the edge of the bag is dry and grease-free in the area of the seam. - Position the open edge of the bag parallel to the sealing bar so that the edge protrudes over the sealing bar by approx. 3/4" (2 cm).
Operation Tips - Freeze liquids before vacuum sealing them. You can then fill the vacuumsealing bags ²/₃ full. - Fold the edges of the vacuum-sealing bag outward for filling. This will give you clean, perfect seams. - If you are unsure whether food such as berries or chips will lose its shape during vacuum sealing, start with the lowest vacuum setting.
Operation Using the vacuum settings There are 3 settings for vacuum sealing. The higher the vacuum setting selected, the greater the vacuum. Vacuum setting Intended use Packaging, portioning, and storing Suitable for - food that is prone to squashing, e.g., lettuce, berries, or chips - single-use jars and jars with twist-off lids (screw-cap lids) with liquid contents, e.g.
Operation Using the sealing levels There are 3 levels for sealing vacuumsealing bags. The choice of sealing level depends on the material thickness of the bag: the thicker the bag, the higher the sealing level. Level 3 is recommended for bags with a thickness of 0.003" (90 µm). Tip: The sealing bar will get progressively hotter when carrying out a number of consecutive vacuuming processes. You can use a lower sealing level after sealing a few bags.
Operation Danger of injury caused by implosion. Damage to the glass lid can cause implosion. Do not under any circumstances use the drawer if the glass lid is damaged. Malfunction can occur due to dirty and/or covered sensor buttons. The sensor buttons do not react or unintentional switching procedures result, perhaps even the automatic deactivation of the drawer. Keep the sensor buttons and indicators clean. Do not place anything over the sensor buttons or indicators. Damage caused by liquids.
Operation Vacuuming and sealing bags Fill the vacuum-sealing bag. Open the drawer and the glass lid. Place the vacuum-sealing bag in the vacuum chamber so that the open end of the bag lies across the sealing bar. Ensure that the edge of the bag is positioned centrally and creasefree on the sealing bar. If a bag is too small and slips into the vacuum chamber, place the vacuumsealing bag support underneath. Switch the drawer on with the On/ Off sensor control.
Operation After the vacuum-sealing process Sealing the bag early A signal sounds. You can end the vacuum-sealing process before reaching the selected vacuum setting and seal the bag early. Open the glass lid. Danger of burning due to hot surfaces. The sealing bar and weld seam are hot. Do not touch the sealing bar or the weld seam immediately after the vacuum-sealing process. Remove the vacuum-sealing bag from the vacuum chamber.
Operation Danger of injury caused by implosion. External glass containers can implode during vacuum sealing. Only vacuum seal vacuum-proof containers made of plastic or stainless steel. Vacuuming sealing external containers The process for vacuum sealing a con® tainer from the caso vacuum-sealing container set is described below. ® We recommend caso vacuum-sealing container sets if you wish to use external containers. These containers can be connected to the drawer using the vacuum adapter supplied.
Operation Place the lid on the container and press it down. Open the drawer and the glass lid. The vacuum-sealing process will start. The Start sensor control goes out and the Stop sensor control lights up. Leave the glass lid open for the entire duration of the vacuum-sealing process. c OP E N b a Place the vacuum adapter over the vacuum pump air-intake valve . Attach the connector to the container lid. Make sure that the closure of the lid is turned to “SEAL” (closed).
Operation After the vacuum-sealing process A signal sounds. Detach the connector from the container lid. Make sure that the closure of the lid is still turned to “SEAL” (closed). Remove the vacuum adapter from the vacuum pump air-intake valve. Before starting a new vacuum-sealing process, check that the vacuum adapter, the tube, and the vacuum chamber are clean and dry. Remove any soiling or liquid residues if necessary.
Operation After use Switch off the drawer with the On/ Off sensor control. Clean and dry the drawer and any accessories as described in “Cleaning and care”. Do not close the glass lid until the vacuum chamber is completely dry. Close the drawer. The last vacuum-sealing setting selected is automatically activated the next time the drawer is switched on, and this is shown in the control field. Canceling a vacuum-sealing process You can cancel a vacuum-sealing process at any time, e.g.
Cleaning and care Risk of injury due to electric Switch the drawer off to clean it. shock. The steam from a steam cleaner could reach live electrical components and cause a short circuit. Do not use a steam cleaner to clean the drawer. The drawer and accessories should be cleaned and dried thoroughly after each use. Danger of burning due to hot surfaces. The sealing bar is hot straight after a vacuum-sealing process. Allow the sealing bar to cool down before cleaning it.
Cleaning and care Cleaning the drawer front and glass lid Cleaning the vacuum adapter Remove soiling and fingerprints with a standard domestic glass cleaner or with a clean, damp microfiber cloth. Clean the vacuum adapter with a clean sponge and a solution of hot water and liquid dish soap or a clean, damp microfiber cloth. After cleaning, wipe the surfaces dry using a soft cloth. Then dry the vacuum adapter with a cloth. Cleaning the vacuum chamber and sealing bar Damage caused by liquids.
Cleaning and care Carrying out a drying cycle When food is vacuum sealed, moisture gets into the oil-circulation system in the vacuum pump. To remove the moisture, it is necessary to run a drying cycle after a particular operating time. The sensor control on the control field of the drawer lights up yellow when a drying cycle needs to be carried out. The sensor control lights up yellow and you can still run another 10 vacuumsealing processes.
Frequently Asked Questions With the help of the following guide minor faults in the performance of the machine, some of which may result from incorrect operation, can be remedied without contacting the Service Department. This guide may help you to find the reason for the fault, and how to correct it. Problem Possible cause and solution The drawer will not open. The safety screws on the back of the drawer have not been removed. Contact Miele Technical Service. The drawer cannot be switched on.
Frequently Asked Questions Problem Possible cause and solution The vacuum-sealing bag was not sealed in time. The required vacuum (vacuum setting 1) for sealing a bag was not achieved. Touch the Seal sensor control again or repeatedly until the vacuum-sealing process ends and the bag is sealed. All the sensor controls have gone out. The glass lid will not open. There was a power failure during the vacuum-sealing process. The vacuum chamber is still under pressure so the glass lid cannot be opened.
Frequently Asked Questions Problem Possible cause and solution The edge of the bag is not completely sealed. The edge of the bag was not positioned centrally along the sealing bar or has slipped. Place the edge of the bag centrally along the sealing bar. Make sure that the edge of the bag is parallel to the sealing bar and protrudes over it by approx. 3/4" (2 cm). If the vacuum-sealing bag is too small, place it on the vacuum-sealing bag support. The vacuum-sealing bag is wider than 9 3/4" (25 cm).
Frequently Asked Questions Problem Possible cause and solution The bag is not maintaining the vacuum even though the weld seam is intact. The vacuum-sealing bag has been damaged by sharp pointed objects, e.g., pointed pasta shapes or a bone. Start the vacuuming process again with a new vacuum-sealing bag, on a lower vacuum level if necessary. Use a third-party container if possible. The weld seam is defective or not properly sealed in one or more places.
Frequently Asked Questions Problem Possible cause and solution The sensor control lights up red. A vacuuming process cannot be started. When vacuum-sealing food, moisture got into the oilcirculation system in the vacuum pump. When the sensor control lights up red, the drawer is locked and cannot be used again. Carry out a drying cycle (see “Cleaning and care – Carrying out a drying cycle”). There is a film of oil on the glass lid and in the drawer.
Frequently Asked Questions Problem Possible cause and solution The vacuum-sealing process is canceled after 5 seconds. A signal sounds and the indicator light lights up red. The glass lid is not sitting evenly. There is an object, such as the edge of a bag or some soiling, on the surface of the chamber seal. Remove the obstruction and/or the soiling. Close the glass lid. Press lightly on the black triangle on the glass lid for approx. 5 seconds. The chamber seal is not installed correctly.
Customer Service Contact in the event of a fault In the event of a fault which you cannot remedy yourself, please contact your Miele dealer or Miele Customer Service. You can book a Miele Service Call online at www.miele.com/service. Contact information for Miele Customer Service can be found at the end of this document. Please quote the model identifier and serial number of your appliance (SN) when contacting Miele Customer Service. Both pieces of information can be found on the data plate.
*INSTALLATION* Installation IMPORTANT SAFETY INSTRUCTIONS - INSTALLATION Risk of damage caused by incorrect installation. Incorrect installation can cause damage to the drawer and/or the combination appliance. The appliance must only be installed by a qualified person. Before connecting the drawer to the line power supply, ensure that the connection data on the data plate (voltage and frequency) match the line power. This data must correspond in order to avoid the risk of damage to the drawer.
*INSTALLATION* Installation Installation notes The drawer is available in 2 models, which differ in height. The building-in dimensions for the drawer must be added to the building-in dimensions for the combination appliance to establish the niche size required.
*INSTALLATION* Installation Installation dimensions EVS 7010 Installation in a tall or base unit If the drawer is to be installed in a housing unit underneath a cooktop, please also observe the installation instructions for the cooktop as well as the casing depth required for the cooktop.
*INSTALLATION* Installation Combination with an H 2840 or CVA/DGC/H 7x4x Miele Drawers can be installed flush or proud. Discuss your requirements with your architect, kitchen designer, and installer. More installation drawings are available on the Miele website.
*INSTALLATION* Installation Combination with a DGC/H 7x6x Miele Drawers can be installed flush or proud. Discuss your requirements with your architect, kitchen designer, and installer. More installation drawings are available on the Miele website.
*INSTALLATION* Installation Side view 48
*INSTALLATION* Installation Connections and ventilation A Cutout (min. 28 sq in/ 18,000 mm²) for power cord, water hoses, and ventilation ! No electrical connection in this area. The socket for the electrical connection must be accessible, e.g., in an adjacent kitchen cabinet.
*INSTALLATION* Installation Installation dimensions EVS 7670 Combination with a CVA/DGC/H 7x7x Miele Drawers can be installed flush or proud. Discuss your requirements with your architect, kitchen designer, and installer. More installation drawings are available on the Miele website.
*INSTALLATION* Installation Combination with a DGC 7x8x Miele Drawers can be installed flush or proud. Discuss your requirements with your architect, kitchen designer, and installer. More installation drawings are available on the Miele website.
*INSTALLATION* Installation Side view 52
*INSTALLATION* Installation Connections and ventilation A Cutout (min. 28 sq in/ 18,000 mm²) for power cord, water hoses, and ventilation ! No electrical connection in this area. The socket for the electrical connection must be accessible, e.g., in an adjacent kitchen cabinet.
*INSTALLATION* Installation Installation The drawer has an integrated vacuum pump which contains oil. To prevent oil from leaking out, the drawer must be transported and stored in a horizontal position only. Do not tilt the drawer and do not stand it up on its edge. Installing the air filter and removing the safety screws Preparing the drawer For safe transportation, the vacuum pump is provided with a transit restraint which must be removed before the drawer is installed.
*INSTALLATION* Installation Screw the air filter onto the vacuum pump using a screwdriver. Remove the safety screws from the back of the drawer. Oil may leak while transporting the drawer. Remove the air filter before transporting the drawer and plug the vacuum pump with the transit restraint again. To remove the air filter and install the transit restraint, carry out these steps in reverse order. Secure the transit restraint to the back of the drawer.
*INSTALLATION* Installation Installing the drawer Installing the anti-tipping mechanism Danger of injury due to incorrect installation. The drawer is heavy and will tip forward when open. Installation must be carried out by two people. Keep the drawer closed until it has been installed to the side walls of the housing unit using the supplied antitipping mechanism. Check that the base on which the drawer will sit is clean and level (use a level).
*INSTALLATION* Installation Installing and connecting the drawer Check that the air filter is installed and the safety screws have been removed from the back of the drawer (see “Installation – Building in”). Connect the power cord to the drawer. Slide the closed drawer into the housing unit. When doing so, make sure that the power cord does not get trapped or damaged. Align the drawer at right angles.
*INSTALLATION* Installation Aligning the front of the drawer After installing the combination appliance, it may be necessary under certain circumstances to align the front of the drawer and adjust the gap between the drawer and the combination appliance. For this purpose, 2 screws can be found behind the front of the drawer which are used to fasten the front to the housing of the drawer. Open the drawer. Loosen the retaining screws on the right and left of the drawer housing.
*INSTALLATION* Installation Electrical connection ATTENTION: Before installation or servicing, disconnect the power supply by either removing the fuse, manually “tripping” the circuit breaker or unplugging the appliance. Pull the plug not the cord. Repairs and service by unqualified persons could be dangerous and the manufacturer will not be held responsible. Installation work and repairs should only be performed by a qualified technician in accordance with all applicable codes and standards.
*INSTALLATION* Installation Connection Make sure that the connection data on the data plate matches that of your electricity supply. Connection data The drawer is ready for connection and equipped with a 6' 6'' (2,000 mm) power cord with an electrical plug. 120 V/15 A/60 Hz Make sure that the connecting socket is accessible after the installation of the drawer. Important – Save these instructions for the local electrical inspector’s use.
Please have the model and serial number of your appliance available when contacting Customer Service. U.S.A. Canada Miele, Inc. Importer Miele Limited National Headquarters 9 Independence Way Princeton, NJ 08540 www.mieleusa.com Customer Support Phone: 888-99-MIELE (64353) info@mieleusa.com International Headquarters Miele & Cie. KG Carl-Miele-Straße 29 33332 Gütersloh Germany Headquarters and Miele Centre 161 Four Valley Drive Vaughan, ON L4K 4V8 www.miele.
EVS 7010, EVS 7670 en-US M.-Nr.