Installation
The drawer has an integrated vac-
uum pump which contains oil.
To prevent oil from leaking out, the
drawer must be transported and
stored in a horizontal position only.
Do not tilt the drawer and do not
stand it up on its edge.
Preparing the drawer
For safe transportation, the vacuum
pump is provided with a transit restraint
which must be removed before the
drawer is installed. The air filter supplied
must be installed in place of the transit
restraint.
There are also 2safety screws on the
back of the drawer to prevent the
drawer from being opened unintention-
ally during transportation and when it is
being removed from the packaging.
Install the air filter before installing
the drawer and remove the safety
screws at the back.
Otherwise the drawer cannot be op-
erated and has to be taken out of the
housing unit.
Keep the transit restraint and safety
screws in case the drawer is trans-
ported again.
The transit restraint can be secured
to the back of the drawer.
Installing the air filter and removing
the safety screws
Slide the cover to the right and re-
move it.
Pull the red transit restraint up and
out using, e.g., universal pliers.