Technical information

Technical Information
G1000 / G2000 Dishwashers
Control
Dial
Position
Function Programming Display
Flashing Rhythm of
Rinse LED
Long Short Display
Pos. 12:
Resetting
standard settings
To move through
the levels, turn the
control dial to the
11 o’clock position.
Press the
Start/Stop button
1x. Turn the Control
dial to the 9 o’clock
position. To reset
all parameters
(modified by
customer) to the
factory setting,
press the Start/Stop
button.
With this
programming
function, all
parameters that
can be modified by
the customer, can
be reset to the
factory setting. If
the Rinse LED is
off, at least one
setting was
modified. If the
Rinse LED flashes,
the parameters are
as in the factory
setting.
- - -
Long Short Display
11 o’clock
Pos. 20: Wash
temperature
modification
To move through
the levels, turn the
control dial to the
11 o’clock position.
Press the
Start/Stop button
3x. Turn the control
dial to the 3 o’clock
position. To change
the temperature,
press the Start/Stop
button.
Options: Rinse LED
is off = wash
temperature per
factory setting;
Rinse LED flashes
= increased wash
temperature. An
increase in wash
temperature with a
resulting extension
in program running
time.
- - -
Table 6-4: G2020 Programming Mode Options (cont. from Table 6-3) (cont. on Table 6-5)
109