Technical information

Technical Information
G1000 / G2000 Dishwashers
Control
Dial
Position
Function Programming Display
Flashing Rhythm of
Rinse LED
Long Short Display
To move through
the levels, turn the
control dial to the
11 o’clock position.
Press the
Start/Stop button
5x. Turn the control
dial to 9 o’clock
position. To change
the setting, press
the Start/Stop
button.
Options: Rinse LED
is off = standard
machine height
(G1xxx); Rinse LED
flashes = XXL units
(G2xxx)
11 o’clock Pos. 36:
Machine
height
setting *2
Pos. 38:
Model
variant
setting *2
To move through
the levels, turn the
control dial to the
11 o’clock position.
Press the
Start/Stop button
6x. Turn the control
dial to 3 o’clock
position. To change
the setting, press
the Start/Stop
button.
Options: Rinse LED
is off = models with
UKT: Gx04x; Rinse
LED flashes =
models without
UKT: Gx02x
- - -
Long Short Display
Pos. 39:
Country
variant
setting *2
To move through
the levels, turn the
control dial to the
11 o’clock position.
Press the
Start/Stop button
6x. Turn the control
dial to 5 o’clock
position. To change
the setting, press
the Start/Stop
button.
The flashing rhythm
of the LED Rinse
shows which
country version is
programmed: 1x =
EUR (Europe); 2x =
AUS (Australia); 3x
= USA, 4x = JPN
(Japan), 5x = I/E
(Italy/Spain), 6x =
SER (Southern
Europe) *3
- - -
Table 6.6: G2020 Programming Mode Options (continued from Table 6-5)
Warning!
Do not change settings in Position 36, 38 or 39. Any changes made will
affect the operation of the dishwasher.
111