Technical information

Technical Information
G1000 / G2000 Dishwashers
Flashing
Rhythm of
Intake/Drain
Lt.
Function Programming Display
Flashing Rhythm of
Sani-Wash Lt.
Long Short Long Short Display
- - P0
3 8
Pos. 38:
Model
variant
setting
(from
software
version ID
no. –818)
*2
Press the Program
button 38 times.
The Rinse & Hold
LED flashes 3
times slowly and 8
times rapidly
intermittently.
Press the
Start/Stop button
as appropriate to
make the desired
setting.
The Rinse LED is off
or flashes. Individual
setting possibilities
depend on model and
whether a circulation
pump with slide
shutter (WAW) and
sensor softener (SEH)
are fitted as follows:
P0 = G12xx, G22xx
(without WAW, without
SEH); P4 = Australian
version G12xx, G22xx
(with WAW, without
SEH).
- 1 P4
Long Short Long Short Display
- 1 P1
- 2 P2
- 3 P3
- 4 P4
- 5 P5
3 9
Pos. 39:
Country
variant
setting
(from
software
version ID
no. –818)
*2
Press the Program
button 39 times.
The Rinse & Hold
LED flashes 3
times slowly and 9
times rapidly
intermittently.
Press the
Start/Stop button
as appropriate to
make the desired
setting.
The Rinse LED is off
or flashes. The
following country
versions can be set:
P1 = EUR (Europe);
P2 = AUS (Australia);
P3 = USA, P4 = JPN
(Japan), P5 = I/E
(Italy/Spain), P6 =
SER (Southern
Europe) *3
- 6 P6
Table 6-20: G2140 Program Mode Options (Continued from Table 6-19)
Warning!
Do not change settings in Position 36, 38 or 39. Any changes made will
affect the operation of the dishwasher.
*1 On models with software version ID no. 769, the “Resetting standard settings” function is
at Pos.19.
*2 If the electronic unit is replaced during service work, it must be programmed as follows:
First set the country variant and model variant, then switch off the unit, repeat the
accessing procedure and set the machine height. Then the on-site water hardness must
be set.
*3 The SER variant includes the following countries: Portugal, France, Netherlands,
Belgium and Great Britain.
Save and quit
Switch off the unit.
133