Technical information

Technical Information
G1000 / G2000 Dishwashers
Flashing
Rhythm of
Gel LED
Flashing Rhythm of
Sani-Wash LED
Function Programming Display
Long Short Long Short Display
- -
Pos. 0:
Software
version ID
check
Do not press the
Gel button. The Gel
LED is off.
The display shows
the software
version ID No., e.g.
-769
- - ID No.
Long Short Long Short Display
- - P0
- 1
Pos. 1:
Reset
Press the Gel
button once. The
Gel LED flashes
once rapidly
intermittently. Press
the program button
as appropriate to
make the desired
setting.
This programmable
function can be
used to reset all
modifiable
parameters (both
customer and
service
programming) to
the standard
settings. The
display shows P
and a digit
alternately: P0 =
Non-standard
settings have been
made; P1 = All
settings reset to
standard settings or
no modifications
have been made.
- P1
-
Long Short Long Short Display
- - P0
- 1 P1
- 2 P2
- 3 P3
- 4 P4
1 9 P19
- 2
Pos.2:
Sensor
softener
activation /
Water
hardness
setting*1
Press the Gel
button 2 times. The
Gel LED flashes 2
times rapidly
intermittently. Press
the program button
as appropriate to
make the desired
setting.
The display shows
P and the digit/s of
the set value
alternately. Setting
range: P0 = Sensor
Softener active. P1
to P4 = without
softener; P5 to P70
= Water hardness,
see Table 6-2.
4 - P40
Long Short Long Short Display
- - P0 (0ml)
- 1 P1 (1ml)
- 2 P2 (2ml)
- 3 P3 (3ml)
- 4 P4 (4ml)
- 5 P5 (5ml)
- 3
Pos 3:
Dispensed
rinse aid
quantity
setting
Press the Gel
button 3 times. The
Gel LED flashes 3
times rapidly
intermittently. Press
the program button
as appropriate to
make the desired
setting.
The display shows
P and a digit
alternately: e.g. P3
(standard setting)
indicates a
dispensed quantity
of 3 ml. Setting
range: 0 ml – 6 ml.
- 6 P6 (ml)
Table 6-38: G1470 / G2470 Programming Mode Options (Continued on Table 6-39)
163