Technical information

Technical Information
G1000 / G2000 Dishwashers
6.5.2.3 G2670 Component Test
After selecting the service mode and successfully accessing the component test
program, individual electrical components can be activated via the program button
(Start/Stop for Integrated models). During this procedure, certain components can
only be activated via special mini-programs.
Test sequence and background information:
V01. R1, Y2, M6, …, wash sequence with heating (mini-program):
This starts with 30 sec. drainage, which begins with pulsed priming (2 sec. on
/ 2 sec. off). The water inlet valve is then activated (on models with and
without slide shutter) until 5.4 l has been taken in. At the same time the water
inlet valve is activated, the slide shutter is set to the middle spray arm
position. After 2.7 l has been registered, the EGS (electronically controlled
water softener) valve is also opened until the total desired intake quantity has
been reached. The circulation pump with switched auxiliary winding is then
operated. At the same time the slide shutter is activated with its setting
alternating at 15 sec. intervals. After a further 60 sec., the heating relay is
switched on for 300 sec. and the water is heated to 122°F. The mini-program
ends with 30 sec. drainage, which begins with pulsed priming (2 sec. on / 2
sec. off).
Note
The mini-program does not include any fault testing function.
V02. 1K1, heating relay:
The heating relay is activated for 60 sec.
V03. M8, drain pump:
The drain pump is activated for 60 sec.
V04. Y2, Y5, water inlet valves with EGS (electronically controlled water softener)
valve (mini-program):
The water inlet valve is activated (on models with and without slide shutter)
until 5.4 l has been taken in. After 2.7 l has been registered, the EGS valve is
also opened until the total desired intake quantity has been reached.
Warning!
If the flow meter is defective, the EGS valve is not activated.
V05. Y5, EGS valve:
The EGS valve is activated for 60 sec.
V06. M6, circulation pump switched winding relay:
189