Technical information

G1000 / G2000 Dishwashers
Technical Information
90
2. Remove the drip pan (5.1.2).
3. Disconnect the electrical connectors.
4. Disconnect the plumbing connections for the feed pipes to the top and
middle spray arms.
5. Disconnect the plumbing connections between the circulation pump and the
sump assembly.
6. Remove the circulation pump.
Important
When installing the circulation pump, the seal must be installed on
the pump. Then slide the circulation pump (with seal installed on the
pump) into the sump housing and secure.