Technical information

Technical Information
G1000 / G2000 Dishwashers
5.4.15.4 Pump Impeller Removal
1. Circulation pump removal (5.4.14).
2. Pump housing cap removal (5.4.15.1).
3. Hold the shaft base with suitable pliers and unscrew the pump impeller clockwise.
5.4.15.5 Pump Housing Removal
1. Circulation pump removal (5.4.14).
2. Pump housing cap removal (5.4.15.1).
3. Pump impeller removal (5.4.15.4).
4. Remove the retaining screws.
5. Turn the pump housing counterclockwise to its stop.
6. Lift the pump housing from its guide.
5.4.15.6 Capacitor Removal
1. Circulation pump removal (5.4.14).
2. Use a socket wrench to release the nut on the capacitor holder.
3. Remove the capacitor.
4. Disconnect its plug connections.
5.4.15.7 Heater Pressure Switch Removal
1. Circulation pump removal (5.4.14).
2. Press the retaining lugs to one side with a suitable screwdriver.
3. Disconnect the plug connections.
4. Remove the pump’s heater pressure switch.
Warning!
To avoid leakages, the sealing rings must always be fitted on the pump’s
heater
p
ressure switch connection stubs.
5.4.15.8 Speed Sensor Removal
95