Technical information

Technical Information
96
G1000 / G2000 Dishwashers
1. Circulation pump removal (5.4.14).
2. Lift the PCB slightly with a pair of needle nose pliers so that it can be gripped with
the hand.
3. Turn the PCB 90° clockwise and remove it.
5.4.16 Drain Pump Removal
1. Remove the non-return valve from the sump under the filter combination.
2. Cover plate removal (5.3.3).
3. Disconnect the pump plug connections.
Figure 5-33: Drain Pump Retaining Clip
4. Open the safety retainer clip with a screwdriver, Fig. 5-33, Pos. 1.
5. Turn the pump clockwise and pull it from its holder, Fig. 5-33, Pos. 2.
Note
When refitting, apply a little water or soap solution to the pump seal as
a slip lubricant. After fitting, check all the pump fastening points.
5.4.17 Float Switch Removal