Operating and Installation instructions
Table Of Contents
- Contents
- IMPORTANT SAFETY INSTRUCTIONS
- Caring for the environment
- Installation
- Installation location
- Installation notes
- Specifications for the plumbed water connection
- Installation dimensions
- Building in the appliance
- Before starting...
- Tools required
- Aligning the installation niche
- Checking the installation niche
- Before installation
- Preparing the installation niche
- Pushing the appliance into the niche
- Aligning the refrigeration appliance
- Securing the appliance in the niche
- Securing the toe-kick board and cover
- Aligning the appliance door
- Water connection
- Electrical connection
- Saving energy
- Guide to the appliance
- Accessories
- Before first use
- Switching on and off
- Selecting additional settings
- The correct temperature
- Using SuperFrost
- Temperature and door alarm
- Adjusting the interior fittings
- Freezing and storing food
- Making ice cubes
- Automatic defrosting
- Cleaning and care
- Water filter
- Frequently Asked Questions
- Causes of noises
- Customer Service
- Declaration of conformity
- Copyrights and licenses
Installation
*INSTALLATION*
19
. . .without partition wall
If the appliances are to be installed next
to each other without a partition wall
between them, they will need to be
joined together with the side-by-side in-
stallation kit. In addition, you must in-
stall the side panel heater to prevent
condensation from forming and any re-
sulting damage.
Specifications for the plumbed
water connection
- The machine may only be connected
to the plumbed water connection by
qualified technicians.
- Connection to the household water
supply must comply with the applica-
ble regulations in the country in
which the machine is being installed.
All units and systems used to supply
water to the machine must also com-
ply with the applicable regulations in
the respective country.
- The water quality must comply with
the requirements for drinking water in
the country in which the machine is
being operated.
- The water pressure must be between
29 and 116psi (2 and 8bar).
- The appliance is only suitable for
connection to a cold water line.
- The appliance may only be con-
nected directly to a fresh water sup-
ply to ensure that water is circulated
in the cold water line.
- A shut-off valve must be provided
between the water line and the water
supply of the building to ensure that
the water supply can be cut off if
necessary.
- Make sure that the shut-off valve is
still accessible after the appliance
has been installed.