Operating and Installation instructions
Table Of Contents
- Contents
- IMPORTANT SAFETY INSTRUCTIONS
- Caring for the environment
- Installation
- Installation location
- Installation notes
- Specifications for the plumbed water connection
- Installation dimensions
- Dimensions of the cabinet front
- Building in the appliance
- Before starting...
- Tools required
- Weight of cabinet front
- Aligning the installation niche
- Checking the installation niche
- Before installation
- Preparing the installation niche
- Pushing the appliance into the niche
- Aligning the refrigeration appliance
- Securing the appliance in the niche
- Preparing the cabinet fronts
- Securing and aligning the cabinet front
- Mounting the fixing brackets
- Securing the covers
- Mounting the cover in a side-by-side combination
- Securing the toe-kick ventilation grille and toe-kick cover
- Water connection
- Electrical connection
- Saving energy
- Guide to the appliance
- Accessories
- Before first use
- Switching on and off
- Selecting additional settings
- The correct temperature
- Using SuperFrost
- Temperature and door alarm
- Adjusting the interior fittings
- Freezing and storing food
- Making ice cubes
- Automatic defrosting
- Cleaning and care
- Water filter
- Frequently Asked Questions
- Causes of noises
- Customer Service
- Declaration of conformity
- Copyrights and licenses
Installation
*INSTALLATION*
50
Unduly high water pressure in the
system can result in damage to the
appliance.
Install a pressure reducing valve if
the water pressure in the system ex-
ceeds 116 psi (8bar).
Do not install the system if the water
pressure exceeds 120 psi (8.3bar).
Contact your plumbing specialist if
you are unsure of your water pres-
sure.
Installing the water hose to the appli-
ance
A faucet must be provided between
the water hose and the plumbed wa-
ter connection to ensure that the wa-
ter supply can be cut off if neces-
sary.
Make sure that the faucet is still ac-
cessible after the appliance has been
installed.
By this time, the installation niche
should already have been prepared so
that the appliance needs only to be
pushed into it.
When installing the water hose, make
sure that it is neither kinked nor dam-
aged.
Position the appliance slightly in front
of the installation niche so that the
faucet can still be accessed.
2
The water connection of the refrigera-
tion appliance is ready for connec-
tion at the rear of the appliance.
Install the water hose onto the wa-
ter connection at the rear of the
appliance. Ensure that it is screwed
into position correctly and watertight.
7/16"
2
Connect the water hose to the
faucet.
Ensure that it is properly screwed into
position.
Slowly open the faucet in the water
supply line and check the whole wa-
ter system for leaks.
The appliance can now be installed in
the niche (see “Installing the appli-