Operation Manual
Table Of Contents
- Contents
- Guide to the appliance 5
- Warning and Safety instructions 7
- Caring for our environment 12
- Before using for the first time 14
- To open the door 14
- To close the door 14
- Safety lock 14
- Water softener 15
- To call up the water hardness level in the display 17
- Before using the appliance for the first time, you require: 18
- Filling the salt reservoir 18
- Salt indicator 19
- Rinse aid 21
- Adding rinse aid 21
- Rinse aid indicator 22
- Setting the rinse aid dosage 23
- Loading the dishwasher 24
- Operation 33
- Additional functions 39
- Cleaning and care 46
- Problem solving guide 51
- Maintenance 59
- After sales service 61
- Programme chart 62
- Optional accessories 66
- Electrical connection 67
- Plumbing 68
- Technical data 70

Cleaning the drain pump and
non-return valve
If the water has not been pumped away
at the end of a programme the drain
pump or the non-return valve might be
blocked. They are, however, easy to
clean.
^
Disconnect the dishwasher from the
mains supply. Switch off at the mains
socket and withdraw the plug.
^
Take the filter combination out of the
wash cabinet (see "Cleaning and
care - Checking the filters in the wash
cabinet").
^ Scoop the water out of the cabinet
using a suitable container or utensil.
^
Press the catch for the non-return
valve inwards a.
^
Lift out the non-return valve b, and
rinse well under running water.
^
Remove all foreign objects from the
non-return valve.
The drain pump is situated under the
non-return valve (see arrow).
^ Remove all foreign objects from the
drain pump (watch out for glass or
bone splinters which are particularly
difficult to detect and could cause
injury). Turn the drain pump impeller
by hand to check that there are no
more obstructions. You will feel a little
resistance when you turn the
impeller.
^
Carefully replace the non-return valve
and secure it with the catch.
,
Ensure that the catch engages
correctly.
Be very careful not to damage
sensitive components when
cleaning the drain pump and the
non-return valve.
Maintenance
60