Operating instructions
Table Of Contents
- Contents
- Description of the machine 4
- Guide to the machine 6
- Warning and safety instructions 11
- Opening and closing the door 16
- Automatic mobile unit recognition (Optional) 17
- Areas of application 21
- Dispensing liquid chemical agents 30
- Operation 34
- Data transfer 39
- Maintenance 40
- Periodic checks 40
- Process validation 41
- Routine checks 41
- Cleaning the filters in the wash cabinet 42
- Sprüharme reinigen 44
- Cleaning the control panel 45
- Cleaning the front of the machine 45
- Cleaning the wash cabinet 45
- Cleaning the door seals 45
- Protein test 45
- Mobile units, modules and inserts 46
- Printer (optional) 47
- After sales service 48
- Converting the type of heating 49
- Electrical connection 50
- Plumbing 51
- Technical data 52
- Special features - OXIVARIO 53
- Disposal of your old appliance or machine 55

Warning and Safety
instructions
,
These warning and safety
instructions are in addition to those
given at the beginning of this
booklet.
H
2
O
2
solution must only be used in
the special containers and
adapters supplied by the Ecolab and
Dr. Weigert companies.
Important: observe the
manufacturer's safety instructions
as given on their safety data sheet.
Be especially careful when
handling H
2
O
2
solution. It is an
irritant chemical.
Observe all current safety instructions
pertaining to its use.
Wear protective gloves and goggles.
Empty containers must be
disposed of in accordance with the
manufacturer's instructions.
H
2
O
2
solution must not be mixed
with other chemicals. This could
cause a serious chemical reaction, e. g.
the release of harmful vapours or
gases.
Connecting the H
2
O
2
solution
container
The connection hose for the H
2
O
2
solution container is identified by a
black label. It is supplied without an
adapter because the system for
drawing the solution out of the
container varies depending on supplier.
^
Connect the supplier's adapter to the
connection hose (black).
^
Then connect this to the H
2
O
2
solution container.
^ Then start the DOS2-FILL
programme.
Unlike with other chemical agents, the
H
2
O
2
solution container must be fully
emptied before it is exchanged for a
new one.
Do not replace the H
2
O
2
solution
container with a new one until the FILL
DOS 2 CONTAINER message is
displayed. After connecting the new
container you must run the DOS2-FILL
programme.
If the message CHECK DISPENSING
SYSTEM 2 appears in the display you
must check the container and all
dispensing tubes and hoses. The
programme will stop automatically.
Special features - OXIVARIO
54