Operating instructions

DOS 3 dispensing (neutralizer)
Setting the neutralizer concentration
Set the neutralizer dispensing concentration according to the manufacturer's
recommendations or to meet specific requirements.
Step Display / Result
^
Activate the programming mode as per
page 35.
^
Press the "Drying" 0 button until E02
appears in the display.
E02
^
Set the program selector to the 6 o'clock
position.
The programmed dispensing
concentration appears in the
display,
e.g., 0.10 = 0.10 %
^ Press or hold down the "Display" ß
button until the required value appears in
the display, e.g., 0.20.
0.20
The dispensing concentration is
now set.
^ Save to memory and exit programming
mode as per page 35.
Dispensing concentration setting:
Setting Dosage
.10 20 ml
.20 30 ml
.30 40 ml
.40 50 ml*
.50 60 ml
.60 70 ml
.70 80 ml
.80 90 ml
.90 100 ml
1.0 110 ml
Programmable functions