Operation Manual

Installation - Hobs with enclosed hotplates
These hobs are classified in Germany
as "Y" class for heat protection. They
must be positioned so that there is ade-
quate ventilation. There may be a wall
at the rear, and wall or tall units at one
side. On the other side however no unit
or divider must stand higher than the
hob.
Because of the heat given off, there
must be a minimum distance as fol-
lows:
40 mm between the worktop
cut-out and adjacent furniture,
e. g. tall unit.
50 mm between the back wall
and the worktop cut-out.
Building-in KM 200
* building-in height
Prepare the worktop cut-out as
shown in the illustrations below.
b Sealing ring
c
Hob
d Worktop
e Clamps
f Screw
Loosen the screws f.
Set the hob unit c into the cut-out
and centre it.
Turn the screws f to the right, until
the clamps
e are firmly attached to
the worktop
d.
Check that the hob unit
c
fits tightly
on to the worktop.
1 2
4
5
3
Installation - Hobs with enclosed hotplates
65