Installation Manual

Dual Fuel Range dimensions
48
HR 1934
Position Dimension Description
min. 36"
(914 mm)
Width of cabinet opening
6“ + + 6" In case of the presence of combustible material an
add
itional minimum clearance of 6“ (each side) is
necessary. Ensure local codes are observed.
37" (940 mm) Minimum distance between the top of the cooking
ar
ea and the bottom of an unprotected
combustible surface.
36" (914 mm) Minimum distance between the top of the cooking
ar
ea and the bottom of the Miele Range Hood
(DAR model with DRxB XL Blower).
30" (762 mm) Minimum distance between the top of the cooking
ar
ea and the bottom of the Miele Range Hood
(DAR model with DRxB XXL Blower).
For all other Hoods, please consult with manufacturer's instructions
for required distances.
approx. 13 3/4"
(350 mm)
Maximum connection width right
and left
Location of
wall
r
eceptacle
approx. 4 1/2"
(115 mm)
Maximum connection height
approx. 2 13/16"
(72 mm)
Maximum connection depth