Place a spirit level across the installa-
tion aids on the appliance door to
check the refrigeration appliance’s
alignment.
Unscrew the adjustable feet
and on both sides at least until the
marking on the plinth has reached the
specified distance of 32mm on the
spacer. The standard dimension of
32mm relates to a niche height of
2134mm.
It is important to adjust the feet to a
height of at least 32mm so that the
ventilation of the refrigeration appli-
ance via the plinth functions correctly.
Risk of damage if the feet are
adjusted too much.
The rear adjustable feet can be dam-
aged.
Unscrew the feet only until the
marking on the plinth is aligned to a
maximum of 62mm (max. niche
height of 2164mm).
Check the alignment of the refrigera-
tion appliance again using the install-
ation aids and the spirit level.
Securing the refrigeration appliance
in the building-in niche
Screw the lugs for the fixing plate
into the cabinets/units above the ap-
pliance.