Operation Manual

Problem solving guide
40
Problem Cause and remedy
The compressor runs
continuously.
This is not a fault. To save energy, the compressor
runs at a lower speed, but for longer, when less cool-
ing is required.
The compressor is
switching on more fre-
quently and for longer
periods of time, so the
temperature in the ap-
pliance is dropping.
The ventilation gaps in the housing unit have been
covered or become too dusty.
Do not block the ventilation gaps.
Dust the ventilation gaps regularly.
The appliance door and the freezer compartment
door have been opened too frequently, or a large
amount of fresh food has been placed inside and/or
frozen at the same time.
Only open the appliance door or freezer compart-
ment door when necessary and for as short a time
as possible.
The required temperature will re-establish itself after a
while.
The appliance door and/or freezer compartment door
are not properly closed.
A thick layer of ice may have formed in the freezer
compartment.
Close the door.
The required temperature will re-establish itself after a
while.
If a thick layer of ice has formed, it will reduce effi-
ciency and increase the energy consumption.
Defrost the freezer compartment and clean it.
The ambient temperature is too high. The higher the
room temperature, the longer the compressor will run
for.
See "Installation - Location".
The appliance was not properly installed in the niche.
See "Installation - Building in the appliance".