Operating and Installation Guide
ManualsBrandsMiele ManualsAll Refrigerator- No Freezer24 Inch Panel Ready Smart Refrigerator Column with 13 Cu. Ft. Capacity, WifiConnect, DynaCool, Push2open, IceMaker, MasterFresh, SuperCool, Sabbath Mode, Active AirClean Filter, BrilliantLight, MasterSensor, and Energy Star: Panel Ready, Right Hinge
Table Of Contents
- Contents
- IMPORTANT SAFETY INSTRUCTIONS
- Caring for the environment
- Installation
- Installation location
- Installation notes
- Installation dimensions
- Dimensions of the cabinet front
- Building in the appliance
- Before starting...
- Tools required
- Weight of cabinet front
- Aligning the installation niche
- Checking the installation niche
- Before installation
- Preparing the installation niche
- Pushing the appliance into the niche
- Aligning the refrigeration appliance
- Securing the appliance in the niche
- Preparing the cabinet fronts
- Securing and aligning the cabinet front
- Mounting the fixing brackets
- Securing the covers
- Mounting the cover in a side-by-side combination
- Securing the toe-kick ventilation grille and toe-kick cover
- Limiting the opening angle of the appliance door
- Electrical connection
- Saving energy
- Guide to the appliance
- Accessories
- Before first use
- Switching on and off
- Selecting additional settings
- The correct temperature
- Using Automatic SuperCool
- Door alarm
- Adjusting the interior fittings
- Storing food in the refrigerator section
- Storing food in the MasterFresh zone
- Automatic defrosting
- Cleaning and care
- Frequently Asked Questions
- Causes of noises
- Customer Service
- Declaration of conformity
- Copyrights and licenses
Installation
*INSTALLATION*
29
Risk of injury and damage due to
tipping refrigeration appliance.
If the anti-tip brackets are fixed too
high up, they cannot be used to
secure the refrigeration appliance.
The distance between the
anti-tip brackets and the refrigeration
appliance must not exceed
5/16" (8mm).
Make sure that the gap between the
refrigeration appliance’s rear wall and
the building-in niche does not exceed
2" (51mm).
Place a wooden wedge behind the
anti-tip brackets if necessary.
While holding the anti-tip brackets in
place, mark the necessary drill holes
on the rear wall of the installation
niche.
Fixing screws for different uses and
types of material are supplied in the
accompanying pack.
Securing to a concrete wall
Securing to a wooden wall