Operation Manual

Aligning the building-in niche
The building-in niche must be carefully
aligned using a spirit level before
installing the appliance. The corners
must be at right angles, as otherwise
the furniture door will not align correctly
with the 4 corners of the building-in
niche.
The side panels of the building-in
niche must be even.
The niche panels must be at least 16
mm thick.
The plinth facing must be at least
13 mm thick (or preferably 19 mm).
Checking the building-in niche
The building-in dimensions now need
to be checked.
Check the position of the electrical
and plumbing connections (see
"Electrical connection" and "Mains
water connection").
Check that all surrounding
furniture/units are securely fixed to
the wall.
Check the surrounding furniture/units
for possible clashes when opening
doors.
Before installation
,
Warning!
This appliance is very heavy and
can tip forwards when the door or
freezer drawer is open.
^ Before installation, take any
accessories out of the appliance
and/or from the back of the
appliance.
^
Remove any cable clips from the
back of the appliance.
^
Check that all parts at the back of the
appliance are unhindered. Carefully
remove any hindrance.
To protect the floor from damage when
installing the appliance,
^
secure an off-cut of flooring (e.g. lino)
to the floor in front of the installation
area.
Installation