Operating instructions/Installation instructions
Table Of Contents
- Contents
- Warning and Safety instructions
- Caring for the environment
- Installation
- Location
- Installation notes
- Specifications for the mains water connection
- Building-in dimensions
- Dimensions of front panels
- Installing the appliance
- Before starting ...
- Tools required
- Weight of the furniture fronts
- Aligning the building-in niche
- Checking the installation niche
- Before installation
- Preparing the building-in niche
- Pushing the refrigeration appliance into the building-in niche
- Aligning the refrigeration appliance
- Securing the refrigeration appliance in the building-in niche
- Preparing to install the front panels
- Securing and aligning the furniture front
- Mounting the fixing brackets
- Securing the covers
- Installing the cover in a side-by-side combination
- Securing the plinth ventilation grille and plinth panel
- Limiting the opening angle of the appliance door
- Mains water connection
- Electrical connection
- Saving energy
- Guide to the appliance
- Accessories
- Initial commissioning
- Switching on and off
- Selecting additional settings
- The correct temperature
- Using Super cool and Super freeze
- Temperature and door alarm
- Adjusting the interior fittings
- Storing food in the refrigerator section
- Storing food in the MasterFresh zone
- Freezing and storing food
- Making ice cubes
- Automatic defrosting
- Cleaning and care
- Water filter
- Problem solving guide
- Noises
- Service
- EU Conformity declaration
- UK Conformity declaration
- Copyrights and Licences
Installation
*INSTALLATION*
21
. . .without partition wall
If the refrigeration appliances are to be
installed next to each other without a
partition wall between them, they will
need to be joined together with the
side-by-side installation kit. In addition,
you must install the side panel heater to
prevent condensation from forming and
any resulting damage.
Specifications for the mains
water connection
- Connection to the water supply must
comply with the applicable regula-
tions in the country where the appli-
ance is being installed.
All appliances and systems used to
supply water to the refrigeration ap-
pliance must also comply with the
applicable regulations in the respect-
ive country.
- The appliance may only be connec-
ted to the mains water supply by suit-
ably qualified persons.
- The quality of the incoming water
must conform to the requirements for
drinking water in the country where
the refrigeration appliance is being
used.
- Connect the stainless steel hose of
the refrigeration appliance to the
fresh water supply and do not con-
nect to a water supply in which the
water might stagnate.
- The refrigeration appliance is only
suitable for connection to a cold wa-
ter line.
- The water pressure must be between
200kPa and 800kPa (2 and 8bar).
- A stopcock must be provided
between the stainless steel hose and
the mains water supply to ensure that
the water supply can be cut off if ne-
cessary.
- Make sure that the stopcock is still
accessible after the refrigeration ap-
pliance has been installed.