Operating instructions/Installation instructions

Installation
*INSTALLATION*
73
Risk of damage due to high
humidity.
In environments with high humidity,
condensation can build up on
external panels of the refrigeration
appliance, which can cause
corrosion.
Install the refrigeration appliance in a
dry and/or air-conditioned room with
sufficient ventilation.
After installation, make sure that the
appliance doors close properly, the
ventilation gaps are not covered and
that the appliance has been installed
in accordance with these operating
and installation instructions.
Climate range
The appliance is designed for use within
a certain climate range (ambient
temperatures) and should not be used
outside this range. The climate range of
the appliance is stated on the data plate
inside the appliance.
Climate range Ambient room
temperature
SN +10to +32°C
N +16to +32°C
ST +16to +38°C
T +16to +43°C
Operating in a room which is too cold
will cause the compressor to switch off
for too long, causing the internal
temperature in the appliance to rise with
the risk of food deteriorating and going
off.
Ventilation
Risk of fire and damage due to
insufficient ventilation.
If the refrigeration appliance is not
ventilated sufficiently, the
compressor will run more frequently
and for longer periods. This will
result in increased energy
consumption and a higher operating
temperature for the compressor. This
may, in turn, cause damage to the
compressor.
Please ensure that there is adequate
ventilation around the refrigeration
appliance.
It is essential to observe the required
ventilation gaps. The ventilation gaps
must not be covered or blocked in
any way.
Air at the back of the refrigeration
appliance gets warm. The appliance
housing unit must therefore be
constructed to allow sufficient space for
ventilation (see “Installation
dimensions”):