Technical data

KFN 14827 SDE ed/cs-1 [mm]
Suitable Side-by-Side partner: K 14820 SD
A 5 x 40 cm cut-out should be provided in the furniture housing unit where a 200 cm
2
ventilation gap is stipulated.
During periods of high humidity, some condensation may appear on outside surfaces of cooling appliances. This condensation will
disappear when humidity levels drop. For prevention it is advisable to install the appliance with sufficient ventilation in a dry and/or an air-
conditioned room. Please ensure that doors are closing and sealing properly.
KFN 9753 iD, KFN 9758 iD-3 [mm]
Suitable Side-by-Side partner: KFN 9753iD + KFN 9758iD-3
K 14820 SD ed/cs [mm]
Suitable Side-by-Side partner: KFN 14827 SDE ed/cs
KFN 14943 SD ed/cs [mm]
Not suitable for Side-by-Side installation
KFN 12923 SD edt-1 [mm]
Not suitable for Side-by-Side installation
KWT 4154 UG-1 [mm]
Two KWT 4154 UG-1 can be installed Side-by-Side
695
(1060)
mm
1772-1788
560-568
550
110
15
38
200cm
2
200cm
2
2100
KWT 6831 SG, KWT 6832 SGS
[mm]
Not suitable for Side-by-Side installation
Building-in diagrams: Refrigeration
Illustration: Installing a freestanding unit in
kitchen cabinetry [mm]
Illustration: Installing a freestanding unit with
cabinet on top and distance to the ceiling [mm]
>10
>40
B
D
>50
C
>40
>10
>50
A
B
D
>50
C
>50
C
• A=Ventductatrearofappliancewitha
depth of approx. 50 mm
• B=Gapbetweentopofmachineand
ceiling at least 40 mm
• C=Wheninstallednexttoawallor
another appliance, a space of approx.
50 mm is needed on the hinge side
between the wall and the appliance to
allow room for the handles and to enable
the door to open fully.
• D=Aspaceof10mmisrequired
between the unit and the wall.
The appliance can be installed in a kitchen
run. To match the height of the rest of the
kitchen, the appliance can be fitted with
a suitable top box. A ventilation gap of at
least 50 mm must be provided behind the
entire width of the top box to allow air to
circulate.
The gap between the machine or top box
and the ceiling should be at least 40 mm
to allow warm air to rise behind the unit.
Otherwise the appliance has to work too
hard, resulting in an increase in electricity
consumption. The larger the cross-section,
the more efficient the appliance.
Initial operation
Temperature settings: Refrigerator section +5°C
Freezer compartment –18°C
Door opening: Not during initial cooling phase
Fan if fitted: Deactivated
Illustration: Gap between hinge and
adjacent wall [mm]
General information for freestanding cooling appliances
installed in a kitchen run
KWT 6831 SG, KWT 6832 SGS
[mm]
Not suitable for Side-by-Side installation
78 79