Operating and Installation instructions
Table Of Contents
- Contents
- IMPORTANT SAFETY INSTRUCTIONS
- Caring for the environment
- Saving energy
- Guide to the appliance
- Switching on and off
- The correct temperature
- Using Automatic SuperCool
- Door alarm
- Selecting additional settings
- Storing food in the refrigerator section
- Storing food in the PerfectFresh zone
- Adjusting the interior fittings
- Defrosting
- Cleaning and care
- Frequently Asked Questions
- Causes of noises
- Customer Service
- Information for dealers
- Installation
- Installation
- Installation dimensions
- Limiting the opening angle of the appliance door
- Changing the door hinging
- Building in the appliance
- Preparing the appliance
- With 5/8" (16 mm) thick cabinet walls only:
- Building in the appliance
- Securing the appliance in the niche
- Only for an appliance with a niche height greater than 55" (140 cm)
- Installing the cabinet door
- Adjusting the position of the door
- X: side adjustments
- Y: height adjustment
- Z: depth adjustment
- Electrical connection
Installation
*INSTALLATION*
66
If you wish to fit a grille in the ventila-
tion openings, the ventilation open-
ings must be larger than 31 square
inches. The passage volume of 31
square inches is the total area of the
opening slits in the grille.
- Important! The larger the ventilation
slits, the more economically the ap-
pliance will work.
The ventilation slits must not be
blocked or obstructed in any way.
Clean the ventilation slits on a regu-
lar basis.
Top ventilation gap
The ventilation gap at the top of the ap-
pliance can be constructed in different
ways:
a
Directly above the appliance with a
ventilation grille (free airflow of at
least 31sqinches (200cm²))
b
Between the kitchen cabinetry and
the ceiling
c
In a suspended ceiling
Lower ventilation slit
The appliance can be ventilated via the
cabinet plinth with the ventilation grille
supplied or with a minimum ventilation
opening of 31 square inches cross-sec-
tion area. When using the grille sup-
plied, please proceed as follows:
Cut an opening in plinth as shown
in the diagram.
Place ventilation grille in the open-
ing.
Push snap fasteners into the venti-
lation grille from behind until the
hooks touch the plinth.
Reinstall the plinth with the ventilation
grille.
Door panel
The required door panel must be min.
5/8” (16mm) and max. 3/4” (19mm)
thick.
Weight of the door panel
If the door panel is too heavy,
this can cause damage!
Installing a door panel which is heav-
ier than the maximum permitted
weight could damage the hinges.
This can cause subsequent func-
tional problems.