Manual
Table Of Contents
- Contents
- IMPORTANT SAFETY INSTRUCTIONS 5
- Guide to the appliance 10
- Accessories 13
- Emergency door opener 14
- How to save energy 15
- Turning the appliance on and off 16
- Selecting additional settings 18
- Temperature and air quality 21
- Temperature and door alarm 26
- Feature lighting 28
- Storing wine bottles 30
- Sommelier set 35
- Automatic defrosting 37
- Cleaning and Care 38
- Active charcoal filter 40
- Frequently asked questions 42
- Noises 47
- After sales service 48
- Information for dealers 49
- Caring for the environment 54
- Electrical connection 55
- Installation 57
- Adjusting the door hinge 62
- Under-counter installation 66
- Contact details 75
![](/manual/miele/kwt6312ugs/manual-english/images/img-53.png)
,
Failure to follow these
instructions can result in death, fire,
or electrical shock.
Improper connection of the
equipment grounding conductor
may result in electric shock.
If you are in any doubt as to whether
the appliance has been properly
grounded, have the appliance
checked by a qualified electrician or
service technician.
Installation, repairs and other work
by unqualified persons could be
dangerous. The manufacturer will
not be held responsible for damage
or injury arising from unauthorized
work.
Before installing the appliance,
verify that the voltage, load and
circuit rating information found on
the data plate match the household
electrical supply.
,
To guarantee the electrical
safety of this appliance, continuity
must exist between the appliance
and an effective grounding system.
It is imperative that this basic safety
requirement be met. If there is any
doubt, have the electrical system of
the house checked by a qualified
electrician.
,
This appliance is equipped with
a three-prong grounding plug to
prevent shock hazards. It should be
plugged directly into a properly
grounded outlet. Do not cut or
remove the grounding prong from
the plug. If the plug does not fit the
outlet, have the proper outlet
installed by a licensed electrician.
Do not use extension cords or
ungrounded (two prong) adapters.
Connect this appliance to a 110 –
120 VAC, 60 Hz and 15 amp (20 amp
for side-by-side) circuit with a circuit
breaker or fuse.
This appliance must be grounded
according to local or national codes.
Electrical connection
53