User manual

29

60 cm wide, cupboard door with slim stainless steel
front panel
InstallatIon
Built into 60 cm wide wall cupboard
Controls
Mechanic slide-switch

2 x 50 W halogen for optimum cooktop illumination
Motor
Double acting radial fan x 1
PerforManCe
Airow in Intensive setting to EN 61951 (with
standard 150 mm duct) up to 430m³/hr

Three + Intensive

Sound power (sound pressure) in Intensive setting
acc. to EN 60704-3 (EN 60704-2-13)
58 dB(A) re 1 pW (45 dB(A) re 20 μPa)
fIltratIon
10-layer stainless steel, dishwasher proof

DUU 151 conversion kit, DKF 13-1 NoSmell active
charcoal lter (optional accessories)

DASD 150 Silencer
DAMK 100-150 Wall vent kit
Da 3060

60 cm wide, cupboard door with slim stainless steel
front panel
InstallatIon
Built into 60 cm wide wall cupboard
Controls
Electronic light-touch

2 x 50 W halogen for optimum cooktop illumination
Motor
Double acting radial fan x 1
PerforManCe
Airow in Intensive setting to EN 61951 (with
standard 150 mm duct) up to 760m³/hr

Three + Intensive, automatic reduction of Intensive
after 10 mins (programmable)

Sound power (sound pressure) in Intensive setting
acc. to EN 60704-3 (EN 60704-2-13)
70 dB(A) re 1 pW (58 dB(A) re 20 μPa)
fIltratIon
10-layer stainless steel, dishwasher proof

DUU 151 conversion kit, DKF 13-1 NoSmell active
charcoal lter (optional accessories)

DASD 150 Silencer
DAMK 100-150 Wall vent kit
DSM 400 Control module to switch rangehood light
on with in-room light switch
Da 3160 Da 3190

90 cm wide, cupboard door with slim stainless steel
front panel
InstallatIon
Built into 60 cm wide wall cupboard
Controls
Electronic light-touch

2 x 50 W halogen for optimum cooktop illumination
Motor
Double acting radial fan x 1
PerforManCe
Airow in Intensive setting to EN 61951 (with
standard 150 mm duct) up to 760m³/hr

Three + Intensive, automatic reduction of Intensive
after 10 mins (programmable)

Sound power (sound pressure) in Intensive setting
acc. to EN 60704-3 (EN 60704-2-13)
70 dB(A) re 1 pW (58 dB(A) re 20 μPa)
fIltratIon
10-layer stainless steel, dishwasher proof

DUU 151 conversion kit, DKF 13-1 NoSmell active
charcoal lter (optional accessories)

DASD 150 Silencer
DAMK 100-150 Wall vent kit
DSM 400 Control module to switch rangehood light
on with in-room light switch
29
1. The front section of the wall housing unit must be tted
with a shelf to the depth of the partition wall.
2. The partition wall must be removable.
3. Extraction mode; measurements of height and cut outs
of installed accessories must be considered (e.g.silencer)
4. Ventilation with conversion kit DUU 151
1. Extraction mode; measurements of height and cut outs
of installed accessories must be considered
(e.g. silencer, DSM-Module)
2. Ventilation with conversion kit DUU 151
3. Accessory DSM 400
1. Extraction mode; measurements of height and cut outs
of installed accessories must be considered
(e.g. silencer, DSM-Module)
2. Ventilation with conversion kit DUU 151
3. Accessory DSM 400
* Can also be tted in a 550 mm wide wall unit