DA 489-4
1) Extraction
2) Recirculation
3) Ventilation grille position at the top for recirculation
4) and 5) Vent cut-out positions (area 5 not required for
recirculation)
* Safety distance between rangehood and cooktop min
350 mm
DESIGN
90 cm wide, stainless steel / clear glass combination,
maximum headroom design
INSTALLATION
Between wall cupboards or stand-alone
CONTROLS
Electronic light-touch
LIGHTING
4 x 20 W halogen for optimum cooktop illumination,
dimmable
SAFETY
Automatic safety cut-out after 10h continuous
operation
MOTOR
Double acting radial fan x 1
PERFORMANCE
Airow in Intensive setting to EN 61951 (with
standard 150 mm duct) up to 640 m³/hr
MOTOR SETTINGS
Three + Intensive, automatic reduction of Intensive
after 10 mins (programmable), selectable fan-run on
time for 5 or 15 minutes
OPERATING SOUND
Sound power (sound pressure) in Intensive setting
acc. to EN 60704-3 (EN 60704-2-13)
64 dB(A) re 1 pW (50 dB(A) re 20 μPa)
FILTRATION
10-layer stainless steel, dishwasher proof
Grease and active charcoal lter change indicator
STANDARD INSTALLATION ACCESSORIES
Telescopic wall bracket
RECIRCULATION OPERATION
DUW 20 conversion kit, DKF 12-1 NoSmell active
charcoal lter (optional accessories)
FURTHER OPTIONAL ACCESSORIES
DASD 150 Silencer
DAMK 100-150 wall vent kit
DSM 400 Control module to switch rangehood light
on with in-room light switch
Con@ctivity for rangehood to be controlled via select
Miele cooktops