Installation plan

en - Technical data
18
Electrical connection EU, CH, CN, RU, UA, KZ
Voltage 3NAC400V /
50Hz
AC230V / 50Hz
Power rating 8.9kW 3.4kW
Fuse rating 3x16A 1x16A
Mains connection cable, min. cross-section 5x2.5mm² 3x1.5mm²
Length of connection cable (H05(07)RN-F) 1.7m 1.7m
Electrical connection BE, NO
Voltage 3AC230V / 50Hz AC230V / 50Hz
Power rating 7.1kW 2.9kW
Fuse rating 3x20A 3x16A
Mains connection cable, min. cross-section 3x1.5mm² 3x1.5mm²
Length of connection cable (H05(07)RN-F) 1.7m 1.7m
Electrical connection AU
Voltage 3NAC400V /
50Hz
AC230V / 50Hz AC230V / 50Hz
Power rating 8.9kW 5.9kW 2.9kW
Fuse rating 3x15–16A 1x30–32A 1x15–16A
Mains connection cable, min. cross-section 5x2.5mm² 3x4mm² 3x1.5mm²
Connection cable length 1.8m 1.9m 1.8m
Electrical connection US, CA
Voltage 2AC 208V 60Hz 3AC 208V 60Hz 3AC 240V 60Hz 2AC 240V 60Hz
Power rating 5.8kW 5.8kW 5.8kW 5.8kW
Fuse rating 2polex30A 3polex20A 3polex20A 2polex30A
Mains connection cable, min. cross-section 3xAWG10
(3x5.2mm²)
4xAWG12
(4x3.3mm²)
4xAWG12
(4x3.3mm²)
3xAWG10
(3x5.2mm²)
Connection cable length approx. 5'9''
(1.8m)
approx. 5'9''
(1.8m)
approx. 5'9''
(1.8m)
approx. 5'9''
(1.8m)
Electrical connection NEMA L6-30 NEMA L15-20 NEMA L15-20 NEMA L6-30