Installation plan
en - Technical data
18
Electrical connection EU, CH, CN, RU, UA, KZ
Voltage 3NAC400V /
50Hz
AC230V / 50Hz
Power rating 8.9kW 3.4kW
Fuse rating 3x16A 1x16A
Mains connection cable, min. cross-section 5x2.5mm² 3x1.5mm²
Length of connection cable (H05(07)RN-F) 1.7m 1.7m
Electrical connection BE, NO
Voltage 3AC230V / 50Hz AC230V / 50Hz
Power rating 7.1kW 2.9kW
Fuse rating 3x20A 3x16A
Mains connection cable, min. cross-section 3x1.5mm² 3x1.5mm²
Length of connection cable (H05(07)RN-F) 1.7m 1.7m
Electrical connection AU
Voltage 3NAC400V /
50Hz
AC230V / 50Hz AC230V / 50Hz
Power rating 8.9kW 5.9kW 2.9kW
Fuse rating 3x15–16A 1x30–32A 1x15–16A
Mains connection cable, min. cross-section 5x2.5mm² 3x4mm² 3x1.5mm²
Connection cable length 1.8m 1.9m 1.8m
Electrical connection US, CA
Voltage 2AC 208V 60Hz 3AC 208V 60Hz 3AC 240V 60Hz 2AC 240V 60Hz
Power rating 5.8kW 5.8kW 5.8kW 5.8kW
Fuse rating 2polex30A 3polex20A 3polex20A 2polex30A
Mains connection cable, min. cross-section 3xAWG10
(3x5.2mm²)
4xAWG12
(4x3.3mm²)
4xAWG12
(4x3.3mm²)
3xAWG10
(3x5.2mm²)
Connection cable length approx. 5'9''
(1.8m)
approx. 5'9''
(1.8m)
approx. 5'9''
(1.8m)
approx. 5'9''
(1.8m)
Electrical connection NEMA L6-30 NEMA L15-20 NEMA L15-20 NEMA L6-30