Installation Plan Professional Dishwasher PG 8056 Mat. no.
Installation instruction Observe installation instructions when installing machine. This dishwasher is suitable for residential and commercial use. Installation Installation should only be carried out by authorized installers in accordance with valid regulations, relevant standards and health and safety codes! Condensate Only use commercial grade cabinetry in the vicinity of this dishwasher as condensate may otherwise cause damage.
Dimensions in drawings in inches & [mm] EL Electrical connection WW Hot water KW Cold water AW Drain water DS External dosing connection (optional) Installation plan PG 8056 page 2 / 6
Dimensions in drawings in inches & [mm] page 3 / 6 Installation plan PG 8056
Electrical connection (208 V) Voltage (default) 2 AC 208V 60 Hz 2 AC 208V 60 Hz Rated load 5.8 kW 5.8 kW Fuse rating 2 × 30 A 2 × 30 A Minimum cross-section 3 × AWG 10 3 × 5.2 mm² Length of electrical cord (UL 921) with plug approx. 5‘ 7“ approx. 1.7 m Electrical connection NEMA L6-30 NEMA L6-30 Voltage (convertible) 3 AC 208V 60 Hz 3 AC 208V 60 Hz Rated load 5.8 kW 5.8 kW Fuse rating 3 × 20 A 3 × 20 A Minimum cross-section 4 × AWG 12 4 × 3.
Hot water connection Max. temperature 149 °F 65 °C Max. water hardness 73 gpg 70 °dH Min. flow pressure 29 psi 200 kPa Min. flow pressure with extended water intake 5.8 psi 40 kPa Max. pressure 145 psi 1,000 kPa Throughput 2 gal/min 7.5 l/min Connection thread - on site (flat sealing) 3/4“ Male Garden Hose Thread 3/4“ Male Garden Hose Thread (USA: 11.5 NH) Length of connection hose (supplied) approx. 5‘ 7“ approx. 1.
Machine data Unit height 32 5/16“ 820 mm Height including cover 32 7/8“ 835 mm Width 23 9/16“ 598 mm Depth 22 13/16“ 580 mm Door height 26 3/8“ 670 mm Net weight 154 lbs 70 kg Dynamic floor load 1.200 N 1.200 N Width including transport pallet 26 3/8“ 670 mm Depth including transport pallet 29 1/8“ 740 mm Height including transport pallet 36 1/4“ 920 mm Ambient temperature 41-104 °F 5-40 °C Set-up conditions Max. humidity up to 88°F / 31°C 80% 80% Max.
U.S.A. Miele, Inc. National Headquarters 9 Independence Way Princton, NJ 08540 Phone: 800‐991‐9380 Fax: 609‐419‐4241 www.mieleusa.com Technical Service & Support Nationwide Phone: 800‐991‐9380 Fax: 800‐220‐1348 proservice@mieleusa.com All rights reserved! Date: 2015‐06‐09 page 7 / 6 Mat. no.