Electrical connection (208 V)
Voltage (default)
2 AC 208V 60 Hz 2 AC 208V 60 Hz
Rated load 5.8 kW 5.8 kW
Fuse rating 2 × 30 A 2 × 30 A
Minimum cross-section 3 × AWG 10 3 × 5.2 mm²
Length of electrical cord (UL 921) with plug approx. 5‘ 7“ approx. 1.7 m
Electrical connection NEMA L6-30 NEMA L6-30
Voltage (convertible)
3 AC 208V 60 Hz 3 AC 208V 60 Hz
Rated load 5.8 kW 5.8 kW
Fuse rating 3 × 20 A 3 × 20 A
Minimum cross-section 4 × AWG 12 4 × 3.3 mm²
Length of electrical cord (UL 921) with plug approx. 5‘ 7“ approx. 1.7 m
Electrical connection NEMA L15-20 NEMA L15-20
Electrical connection (240 V)
Voltage (default)
2 AC 240V 60 Hz 2 AC 240V 60 Hz
Rated load 5.8 kW 5.8 kW
Fuse rating 2 × 30 A 2 × 30 A
Minimum cross-section 3 × AWG 10 3 × 5.2 mm²
Length of electrical cord (UL 921) with plug approx. 5‘ 7“ approx. 1.7 m
Electrical connection NEMA L6-30 NEMA L6-30
Voltage (convertible)
3 AC 240V 60Hz 3 AC 240V 60Hz
Rated load 5.8 kW 5.8 kW
Fuse rating 3 × 20 A 3 × 20 A
Minimum cross-section 4 × AWG 12 4 × 3.3 mm²
Length of electrical cord (UL 921) with plug approx. 5‘ 7“ approx. 1.7 m
Electrical connection NEMA L15-20 NEMA L15-20
Cold water connection
Max. temperature 68 °F 20 °C
Max. water hardness 73 gpg 70 °d
Min. flow pressure 29 psi 200 kPa
Min. flow pressure with extended water intake 5.8 psi 40 kPa
Max. pressure 145 psi 1,000 kPa
Throughput 2 gal/min 7.5 l/min
Connection thread - on site (flat sealing)
3/4“ Male Garden Hose
Thread
3/4“ Male Garden
Hose Thread
(USA: 11.5 NH)
Length of connection hose (supplied) approx. 5‘ 7“ approx. 1.7 m
