Descriptive Technical Documentation - Model-dependent - DTD no. 521-7135 Model(s): PT 7135 C, PT 7136, PT 5135 C, PT 5136 14.10.2005, DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
This information should not be duplicated or passed on without Miele approval. All rights reserved. 14.10.
Descriptive Technical Documentation 1 DTD no. 521-7135 Contents General Information A Warning and Safety Instructions B Modification History C Technical Data D Layout of Electrical Components Function Groups 020 030 040 070 080 14.10.2005, DE_en Door 2 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 020-2 2.1 Door lock (A2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Descriptive Technical Documentation DTD no. 521-7135 2 2.4 2.5 2.6 2.7 2.20 2.21 2.22 Time of day programmable function . . . . . . . . . . . . . . . . . . . . . . . Extended cooling phase programmable function. . . . . . . . . . . . . Residual moisture level adjustment programmable function. . . . Clean the airways warning modification programmable function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Automatic programmable function. . . . . . . . . . . . .
Descriptive Technical Documentation 3 DTD no. 521-7135 4.6 090 080-38 Electrical components 2 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 090-2 2.1 2.2 2.3 2.4 Mains terminal strip (X3/1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Payment system socket (X1/1) . . . . . . . . . . . . . . . . . . . . . . . . . . . Payment system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 This information should not be duplicated or passed on without Miele approval. All rights reserved. Descriptive Technical Documentation DTD no. 521-7135 14.10.
DTD no. 521-7135 Descriptive Technical Documentation A-1 A Warning and Safety Instructions 1 General information Service and repair work should only be carried out by suitably qualified persons in accordance with all appropriate local and national safety regulations. Servicing, modification, testing and maintenance of electrical appliances should only be carried out in accordance with all appropriate legal requirements, accident prevention regulations and valid standards.
Descriptive Technical Documentation DTD no. 521-7135 A-2 2 Risk of injury due to sharp edges There may be a risk of injury due to sharp edges. Protective gloves should be worn and the edge protection, Mat. no. 05057680, should be used. This information should not be duplicated or passed on without Miele approval. All rights reserved. 14.10.
DTD no. 521-7135 3 Descriptive Technical Documentation A-3 Electrical connection via plug connector It is always recommended to make electrical connection via a plug and socket so that electrical safety checks, e.g. during repair or service work, can be carried out easily. The socket must be accessible after machine installation. This also applies even if an on-site mains switch is also already provided.
Descriptive Technical Documentation DTD no. 521-7135 A-4 4 Touch current measurement x Note On machines with an earth connection, touch current leakage measurements should be carried out on all accessible conductive parts that are not connected to the earth.
Descriptive Technical Documentation B-1 DTD no. 521-7135 B 14.10.2005, DE_en Modification History When? Who? What? 11.05.2005 Olaf Meyer zu Drewer Initial compilation This information should not be duplicated or passed on without Miele approval. All rights reserved.
B-2 This information should not be duplicated or passed on without Miele approval. All rights reserved. Descriptive Technical Documentation DTD no. 521-7135 14.10.
Descriptive Technical Documentation C-1 DTD no. 521-7135 C Technical Data Semi-commercial machines PT 7135 C PT 7136 PT 5135 C PT 5136 Condenser dryer Vented dryer Condenser dryer Vented dryer Casing Generation 2000, spaceframe construction - Filter flap / Cover Door Filter flap / Cover Door opened mechanically via pushbutton switch with Bowden cable Door lock contact switch (A2) Drum, bearing, sensors, heater bank Maximum load, dry laundry, 6.
C-2 This information should not be duplicated or passed on without Miele approval. All rights reserved. Descriptive Technical Documentation DTD no. 521-7135 14.10.
DTD no. 521-7135 D Descriptive Technical Documentation D-1 Layout of Electrical Components PT 7135 C x Layout 1 1 (Z1) 2 X3/1 3 (1K1/1, 2K1/1, 3K1/1) 4 (X1/1) P6 P8 5 (1N1) 6 (2N1) 7 (F7) 8 (S4) 9 (H3/6) 10 (1F2, 2F2) 14.10.
Descriptive Technical Documentation DTD no. 521-7135 D-2 11 (2R30) 12 (R1, R2, R3) 13 (A2) 14 (C5) 15 (M5) 16 (1R30) 17 (M13) 18 (B8/7) 19 (B3/1) Drying air NTC temperature sensor - In heater bank behind perforated rear drum panel Heater bank Door lock Capacitor - Drum drive Motor - Air flow and drum drive Drying air NTC temperature sensor - Fill ring Motor - Condensate pump Float switch - Condensate Sensor - Residual moisture This information should not be duplicated or passed on without Miele approval.
DTD no. 521-7135 Descriptive Technical Documentation D-3 PT 5135 C x Layout 2 1 (Z1) 2 X3/1 3 (1K1/1, 2K1/1, 3K1/1) 4 (X1/1) P6 P8 5 (1N1) 6 (2N1) 7 (F7) 8 (S4) 9 (H3/6) 10 (1F2, 2F2) 11 (2R30) 14.10.
Descriptive Technical Documentation DTD no. 521-7135 D-4 12 (R1, R2, R3) 13 (A2) 14 (C5) 15 (M5) 16 (1R30) 17 (M13) 18 (B8/7) 19 (B3/1) Heater bank Door lock Capacitor - Drum drive Motor - Air flow and drum drive Drying air NTC temperature sensor - Fill ring Motor - Condensate pump Float switch - Condensate Sensor - Residual moisture This information should not be duplicated or passed on without Miele approval. All rights reserved. 14.10.
DTD no. 521-7135 Descriptive Technical Documentation D-5 PT 7136 x Layout 3 1 (Z1) 2 (X3/1) 3 (1K1/1, 2K1/1, 3K1/1) 4 (X1/1) P6 P8 5 (M2) 6 (1N1) 7 (2N1) 8 (F7) 9 (S4) 10 (H3/6) 11 (2R30) 14.10.
Descriptive Technical Documentation DTD no. 521-7135 D-6 12 (A2) 13 (C5) 14 (M5) 15 (S32) 16 (1R30) 17 (R1, R2, R3) 18 (1F2, 2F2, 3F2) 19 (B3/1) Door lock Capacitor - Drum drive Motor - Air flow and drum drive Safety switch - Finger protection Drying air NTC temperature sensor - Fill ring Heater bank Temperature limiter (vented operation) Sensor - Residual moisture This information should not be duplicated or passed on without Miele approval. All rights reserved. 14.10.
DTD no. 521-7135 Descriptive Technical Documentation D-7 PT 5136 x Layout 4 1 (Z1) 2 (X3/1) 3 (1K1/1, 2K1/1, 3K1/1) 4 (X1/1) P6 P8 5 (M2) 6 (1N1) 7 (2N1) 8 (F7) 9 (S4) 10 (H3/6) 11 (2R30) 14.10.
Descriptive Technical Documentation DTD no. 521-7135 D-8 12 (A2) 13 (C5) 14 (M5) 15 (1R30) 16 (R1, R2, R3) 17 (1F2, 2F2, 3F2) 18 (B3/1) Door lock Capacitor - Drum drive Motor - Air flow and drum drive Drying air NTC temperature sensor - Fill ring Heater bank Temperature limiter Sensor - Residual moisture This information should not be duplicated or passed on without Miele approval. All rights reserved. 14.10.
DTD no. 521-7135 020 Descriptive Technical Documentation 020-1 Door x 14.10.2005, DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
Descriptive Technical Documentation DTD no. 521-7135 020-2 2 Function 2.1 Door lock (A2) Door release via Bowden cable. An open door is registered via a microswitch in the door lock. Microswitch in door lock (A2): Drum door open = Contact open. This information should not be duplicated or passed on without Miele approval. All rights reserved. 14.10.
DTD no. 521-7135 030 Descriptive Technical Documentation 030-1 Drum, bearing, sensors, heater bank x 14.10.2005, DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
Descriptive Technical Documentation DTD no. 521-7135 030-2 1 Technical Data Heater bank (R1, R2, R3) Condenser dryer Vented dryer Heater rating with 230 V connection 3-filament, 2-phase 3-filament, 3-phase 1.94 kW + 0.71 kW + 0.8 kW = 3.45 kW 1.94 kW + 2.1 kW + 2.1 = 6.14 kW Table 1: Heater bank (R1, R2, R3) Temperature (°C) Resistance (kΩ) 0 340 5 261 10 203 15 159 20 126 25 100 30 80.2 35 64.8 40 52.7 45 43.1 50 35.5 55 29.4 60 24.5 65 20.5 70 17.3 75 14.
Descriptive Technical Documentation 030-3 DTD no. 521-7135 Temperature (°C) Resistance (kΩ) 190 0.852 200 0.710 Table 2: NTC temperature sensor - Heater bank (2R30) - Resistance values Temperature (°C) Resistance (kΩ) 0 38.0 5 29.7 10 23.4 15 18.6 20 14.9 25 12.0 30 9.73 35 7.96 40 6.55 45 5.42 50 4.52 55 3.78 60 3.19 65 2.70 70 2.29 75 1.96 80 1.68 85 1.45 90 1.25 93 1.15 95 1.09 100 1.06 110 0.73 120 0.569 130 0.449 140 0.358 150 0.
Descriptive Technical Documentation DTD no. 521-7135 030-4 2 Function 2.1 Heating control (R1, R2, R3) Safety features: If the fill ring temperature sensor (1R30) is defective, the heating is not activated. The heating is switched off as soon as the heating relay is switched on for more than 5 s without the fan relay being activated. The heating has a reswitch-on delay of 10 s and is switched off before, during and after a reversing pause. 2.
DTD no. 521-7135 2.5 Descriptive Technical Documentation 030-5 Light - Drum (H3/6) Lighting is time-controlled. It is switched on approx. 1 s after the door is opened. Switch off delay: 5 min. When the door is closed, the lighting is always switched off. 14.10.2005, DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
030-6 This information should not be duplicated or passed on without Miele approval. All rights reserved. Descriptive Technical Documentation DTD no. 521-7135 14.10.
DTD no. 521-7135 040 Descriptive Technical Documentation 040-1 Drive x 14.10.2005, DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
Descriptive Technical Documentation DTD no. 521-7135 040-2 1 Technical Data Cooling fan flow rate Cooling air Drying air Condenser dryer Vented dryer 3 – 3 300 m3 / h. With 20 m vent duct > 200 m3 / h 300 m / h 120 m / h Table 1 This information should not be duplicated or passed on without Miele approval. All rights reserved. 14.10.
DTD no. 521-7135 Descriptive Technical Documentation 040-3 2 Function 2.1 Motor - Air flow and drum drive (M5) PT 7135 C, PT 5135 C The motor drives the drum, drying air fan and cooling air fan at the same time. 2.2 Motor - Air flow and drum drive (M5) PT 7136, PT 5136 The motor drives the drum and drying air fan at the same time. 14.10.2005, DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
040-4 This information should not be duplicated or passed on without Miele approval. All rights reserved. Descriptive Technical Documentation DTD no. 521-7135 14.10.
Descriptive Technical Documentation 070-1 DTD no. 521-7135 070 Condensate pump (M5) PT 7135 C, PT 5135 C x 14.10.2005, DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
Descriptive Technical Documentation DTD no. 521-7135 070-2 2 Function 2.1 Level sensing - Float switch - Condensate (B8/7) Level sensing is via a reed switch. This information should not be duplicated or passed on without Miele approval. All rights reserved. 14.10.
DTD no. 521-7135 080 Descriptive Technical Documentation 080-1 Fascia panel x 14.10.2005, DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
Descriptive Technical Documentation DTD no.
Descriptive Technical Documentation 080-3 DTD no. 521-7135 2 Function 2.1 Overriding time control After programme start, an overriding time control of approx. 180 min applies to all residual moisture drying programmes. After this time has expired, the drying programme is cancelled and the cooling stage for faults is activated. The anti-crease action phase is cancelled. The fault is saved and can be called up in the service mode. 2.
Descriptive Technical Documentation DTD no. 521-7135 080-4 2.5 Extended cooling phase programmable function An extended cooling phase means that the laundry temperature is lower at the end of the programme. A lower laundry temperature reduces the perception of dampness in the load. Extended cooling has no effect with timed programmes. 2.6 Residual moisture level adjustment programmable function The standard residual moisture levels can be modified to make them dryer or damper.
Descriptive Technical Documentation 080-5 DTD no. 521-7135 2.7 Clean the airways warning modification programmable function This function can be used to modify the circumstances under which the Clean the airways warning is displayed to suit individual requirements, see the operating instructions or programming mode. PT 7135 C and PT 7136: Service Dept. programming mode, see Programming mode summary, 080 4.1.
Descriptive Technical Documentation DTD no. 521-7135 080-6 2.10 Clean heat exchanger programmable function PT 7135 C, PT 5135 C With a condenser dryer this warning is shown at intervals and indicates that the heat exchanger must be cleaned regularly. This function can be used to modify the circumstances under which the Clean heat exchanger warning is displayed to suit individual requirements, see the operating instructions or programming mode. PT 7135 C: Service Dept.
Descriptive Technical Documentation 080-7 DTD no. 521-7135 2.13 Payment system programmable function This is used to set the type of payment system. The appropriate operating procedure is shown in the display. For payment system details, see 090 2.3 Payment system. PT 7135 C and PT 7136 only: For central control via RS 232 interface, see 090 2.4 Central control via RS 232 interface with 9-pole plug 2.
Descriptive Technical Documentation DTD no. 521-7135 080-8 2.16 Overriding time control modification programmable function with payment system operation To reduce the possibility of unauthorised manipulation with payment system operation, the overriding time can be reduced. For overriding time control details, see 080 2.1 Overriding time control. 2.
DTD no. 521-7135 2.19 Descriptive Technical Documentation 080-9 Warm air timed programme maximum duration setting programmable function This is used to set the maximum duration of the Warm air timed programme. PT 7135 C and PT 7136: The programme duration can be reduced via the multifunction selector switch but cannot be increased again. PT 5135 C and PT 5136: The programme duration can be reduced via the + / buttons, but cannot be increased again. 2.
Descriptive Technical Documentation DTD no. 521-7135 080-10 3 Fault Repair 3.1 Warning indication: Clean filter PT 7136 Cause This warning is given at certain intervals as a reminder that the filters must be cleaned. Remedy x Note Clean the fluff filters regularly, see the operating instructions. A Clean both parts of the large surface area filter behind the service panel and the filters in the door opening. Cause Clean filter warning shown too soon/late.
DTD no. 521-7135 3.2 Descriptive Technical Documentation 080-11 Warning indication: Clean heat exchanger PT 7135 C, PT 5135 C Cause With a condenser dryer this warning is shown at intervals and indicates that the heat exchanger must be cleaned regularly. Remedy x Note Clean the heat exchanger regularly, see the operating instructions. A Clean the heat exchanger. Cause Clean heat exchanger warning shown too soon/late.
Descriptive Technical Documentation DTD no. 521-7135 080-12 3.3 Warning indication: Adjust the load – The drum is empty or the laundry too dry Symptom This warning can only be displayed with residual moisture drying programmes (i.e. not timed drying). The programme is cancelled, a cooling phase is started and the buzzer sounds intermittently. This warning is cancelled when the door is opened. Cause The drum is empty or loaded with a few small items only.
Descriptive Technical Documentation 080-13 DTD no. 521-7135 3.4 Demonstration mode active Symptom A programme start is not possible and the programming and service modes cannot be accessed. Cause The demonstration mode is active. Remedy A PT 7135 C and PT 7136: Demonstration mode deactivation, see Demonstration mode activation / deactivation, 080 4.3. A PT 5135 C and PT 5136: Demonstration mode deactivation, see Demonstration mode activation / deactivation, 080 4.4. 3.
Descriptive Technical Documentation DTD no. 521-7135 080-14 Remedy A Check the condensate pump (M13). Exchange it if necessary. A PT 7135 C and PT 7136: Service mode, see Service mode summary, 080 4.5. A PT 5135 C and PT 5136: Service mode, see Service mode summary, 080 4.6. Cause The condensate drainage path is blocked. Remedy A Check the drainage path for blockages. Repair as necessary. 3.6 Fault indication: Clean the airways Symptom The programme continues normally or is interrupted.
Descriptive Technical Documentation 080-15 DTD no. 521-7135 Cause Clean the airways warning shown too early/late. Remedy A The point at which the Clean the airways warning is shown can be adjusted to suit the needs of the operator, see the operating instructions or programming mode. A PT 7135 C and PT 7136: For Service Dept. programming mode see Programming mode summary, 080 4.1. A PT 5135 C and PT 5136: For Service Dept. programming mode see Programming mode summary, 080 4.2. 3.
Descriptive Technical Documentation DTD no. 521-7135 080-16 3.8 Fault code F1, heater bank NTC sensor short-circuited Symptom In normal operation mode the display shows Technical fault. Programme interruption, cooling down phase, intermittent buzzer operation. Only the Cool air timed programme can be operated. This fault indication is deleted by pressing the multifunction selector switch. Cause Heater bank temperature sensor (2R30) short-circuited (> 250°C).
Descriptive Technical Documentation 080-17 DTD no. 521-7135 Cause Heater bank not heating. Remedy A Check the heater bank (R) for short or open circuit. Cause Heating relay (K1). Remedy A Check the heating relay (K1). Cause Temperature limiter (F2). Remedy A Check the temperature limiter F2 for continuity. 3.10 Fault code F3, fill ring NTC sensor short-circuited Symptom In normal operation mode the display shows Technical fault. Programme interruption, cooling down phase, intermittent buzzer operation.
Descriptive Technical Documentation DTD no. 521-7135 080-18 3.11 Fault code F4, fill ring NTC sensor open-circuited Symptom In normal operation mode the display shows Technical fault. Programme interruption, cooling down phase, intermittent buzzer operation. Only the Cool air timed programme can be operated. This fault indication is deleted by pressing the multifunction selector switch. Cause Fill ring temperature sensor (1R30) open-circuited (< 15°C).
DTD no. 521-7135 3.13 Descriptive Technical Documentation 080-19 Fault code F43, model type not programmed Cause In normal operation mode this fault is not indicated via the display. The selection module (EW) and power-programme module (ELP) do not match. Remedy A Check the Mat. nos. to verify that the correct selection module (EW) and power-programme module (ELP) are fitted. 3.14 Fault code F45, faulty flash RAM/ data fault Symptom In normal operation mode the display shows Technical fault.
Descriptive Technical Documentation DTD no. 521-7135 080-20 3.15 Fault code F46, display fault Symptom Programme interruption, cooling down phase, intermittent buzzer operation. Cause Internal display fault on selection module (EW). Display driver for LCD module defective. Remedy A Exchange the selection module (EW). 3.16 Fault code F47, communication fault between selection module (EW) and power-programme module (ELP) Symptom In normal operation mode the display shows Technical fault.
Descriptive Technical Documentation 080-21 DTD no. 521-7135 3.17 Fault code F50, motor stationary and heating operates for 5 s Symptom The motor for air flow and drum drive (M5) is stationary. This fault occurs in normal operating mode and the following occurs: Programme interruption, cooling down phase, intermittent buzzer operation for 2 min. This warning is cancelled when the door is opened. Cause The heating has operated for longer than 5 s with the motor stationary.
Descriptive Technical Documentation DTD no. 521-7135 080-22 Cause Air path clogged. Remedy A Check and clean the air paths. Cause Heater bank not heating. Remedy A Check the heater bank (R1) for short or open circuit. Cause Heating relay (K1/1). Remedy A Check the heating relay (K1/1). Cause Temperature limiter (F2). Remedy A Check the temperature limiter (F2) for continuity. Cause Residual moisture sensor (B3/1) defective.
Descriptive Technical Documentation 080-23 DTD no. 521-7135 3.19 Fault code F66, air leakage fault Symptom In normal operation mode the display shows Clean the airways. Cause Air path clogged. Insufficient air flow registered, see 080 2.3 Insufficient air flow measurement. Remedy A Check and clean the air paths. 14.10.2005, DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
Descriptive Technical Documentation DTD no. 521-7135 080-24 4 Service 4.1 Programming mode summary PT 7135 C, PT 7136 Initial requirements A Finish or cancel any programme in operation, including the demonstration mode. A Open the door. A Disconnect the fill ring NTC temperature sensor (1R30) plug. x Note If the fill ring NTC temperature sensor (1R30) plug is disconnected at the powerprogramme module (1N1), then power is also no longer supplied to the door lock (A2).
DTD no. 521-7135 Descriptive Technical Documentation 080-25 Options The set option is indicated by a V next to it. A Programmable function selection: Turn the multifunction selector switch to mark the desired function and press the multifunction selector switch to confirm the selection. A Option selection: Turn the multifunction selector switch to mark the desired option and press the multifunction selector switch to confirm the selection. x Note Highlighted options are standard settings.
Descriptive Technical Documentation DTD no. 521-7135 080-26 x Programmable function Option Language Language for operating, programming and service modes Sort language Select and sort four favourite languages for international installations Anti-crease action Off On Buzzer Off Normal Loud Clock display, see 080 2.
Descriptive Technical Documentation 080-27 DTD no. 521-7135 Programmable function Option Clean filters warning, vented dryers only, see 080 2.9 Clean filters programmable function Off Display after 5 h Display after 10 h Display after 15 h Display after 20 h Display after 25 h Display after 30 h Display after 35 h Display after 40 h Display after 45 h Display after 50 h Display after 55 h Clean heat exchanger warning, condenser dryers only, see 080 2.
Descriptive Technical Documentation DTD no. 521-7135 080-28 Programmable function Option Overriding time control modification with payment system operation, see 080 2.16 Overriding time control modification programmable function with payment system operation 120 min 135 min 150 min 165 min 180 min 195 min 210 min 225 min 240 min Programme lock with payment system operation after releasing the Start button, see 080 2.
Descriptive Technical Documentation 080-29 DTD no. 521-7135 Save and quit x Note Confirmed programmable options are saved. A Reconnect the fill ring NTC temperature sensor (1R30) plug. 4.2 Programming mode summary PT 5135 C, PT 5136 Initial requirements A Finish or cancel any programme in operation, including the demonstration mode. A Open the door. A Disconnect the fill ring NTC temperature sensor (1R30) plug.
Descriptive Technical Documentation DTD no. 521-7135 080-30 The display shows the Service Dept. programmable functions. If the accessing procedure has been unsuccessful, the control automatically reverts to the normal operating mode. Options A Programmable function selection: Press the + / - buttons as appropriate to mark the desired function and press the OK button to confirm the selection. The set option is indicated by a V next to it.
Descriptive Technical Documentation 080-31 DTD no. 521-7135 Programmable function Option Residual moisture level adjustment Minimum iron The standard residual moisture levels can be modified to make them up to 3 stages dryer or damper, see 080 2.6 Residual moisture level adjustment programmable function Residual moisture level adjustment Machine iron The standard residual moisture levels can be modified to make them dryer or damper, see 080 2.
Descriptive Technical Documentation DTD no. 521-7135 080-32 Programmable function Option Programme lock with payment system operation after releasing the Start button, see 080 2.17 Programme lock programmable function with payment system operation None Immediately 1 min 2 min 3 min 4 min 5 min Cool air timed programme maximum duration, see 080 2.
Descriptive Technical Documentation 080-33 DTD no. 521-7135 4.3 Demonstration mode activation / deactivation PT 7135 C, PT 7136 Initial requirements A Finish or cancel any programme in operation. A Open the door. A If the international multilingual start screen is shown, select the desired language. Accessing x Note After it is begun, the accessing procedure must be completed within 10 s. A Press and hold the Start button. A Close the door.
Descriptive Technical Documentation DTD no. 521-7135 080-34 Save and quit A Demonstration programme deactivation: Repeat the accessing procedure. 4.4 Demonstration mode activation / deactivation PT 5135 C, PT 5136 Initial requirements A Finish or cancel any programme in operation. A Open the door. Accessing x Note After it is begun, the accessing procedure must be completed within 10 s. A Press and hold the Start button. A Close the door. A As soon as the Start LED lights up constantly, after approx.
Descriptive Technical Documentation 080-35 DTD no. 521-7135 x Note After an interruption in the mains supply, the demonstration mode programme begins again automatically. Save and quit A Demonstration programme deactivation: Repeat the accessing procedure. 4.5 Service mode summary PT 7135 C, PT 7136 Initial requirements A Ensure the machine is installed and connected correctly. A Finish or cancel any programme in operation, including the demonstration mode. A Open the door.
Descriptive Technical Documentation DTD no. 521-7135 080-36 Options A Service function selection: Turn the multifunction selector switch as appropriate. A Service function start and test step advance: Press the multifunction selector switch. x Note The service mode is switched off automatically 30 min after the last service function has been checked. Service function Component / Sensor tested Selection module (EW) ID no. Power-programme module (ELP) ID no.
Descriptive Technical Documentation 080-37 DTD no. 521-7135 Service function Component activation Component / Sensor tested Component activation Function tested/Machine response All components Inactive Drive/Fan motor (M5) Drum turns with reversing as follows: 10 s anticlockwise, 2.5 s pause, 10 s clockwise, 2.5 s pause, etc. Heating 1 and drive/fan motor (M5) The heating relay 1K1/1 is activated and the drum turns with reversing as follows: 600 s anticlockwise, 2.5 s pause, 10 s clockwise, 2.
Descriptive Technical Documentation DTD no. 521-7135 080-38 Quit (without saving) A Open the door. 4.6 Service mode summary PT 5135 C, PT 5136 Initial requirements A Ensure the machine is installed and connected correctly. A Finish or cancel any programme in operation, including the demonstration mode. A Open the door. Accessing x Note After it is begun, the accessing procedure must be completed within 10 s. A Press and hold the Start button. A Close the door.
Descriptive Technical Documentation 080-39 DTD no. 521-7135 x Note The service mode is switched off automatically 30 min after the last service function has been checked. Service function Software version Fault register display1) and deletion2) 14.10.2005, DE_en Component / Sensor tested Selection module (EW) ID no. Power-programme module (ELP) ID no.
Descriptive Technical Documentation DTD no. 521-7135 080-40 Service function Component activation Component / Sensor tested Component activation Function tested/Machine response All components Inactive Drive/Fan motor (M5) Drum turns with reversing as follows: 10 s anticlockwise, 2.5 s pause, 10 s clockwise, 2.5 s pause, etc. Heating 1 and drive/fan motor (M5) The heating relay 1K1/1 is activated and the drum turns with reversing as follows: 600 s anticlockwise, 2.5 s pause, 10 s clockwise, 2.
Descriptive Technical Documentation 080-41 DTD no.
080-42 This information should not be duplicated or passed on without Miele approval. All rights reserved. Descriptive Technical Documentation DTD no. 521-7135 14.10.
Descriptive Technical Documentation 090-1 DTD no. 521-7135 090 Electrical components x 14.10.2005, DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
Descriptive Technical Documentation DTD no. 521-7135 090-2 2 Function 2.1 Mains terminal strip (X3/1) PT 7136, PT 5136 Depending on the country version, the mains terminal strip (X3/1) has a 4-/5-pole connection cable with strain relief. 2.
Descriptive Technical Documentation 090-3 DTD no. 521-7135 2.4 Central control via RS 232 interface with 9-pole plug PT 7135 C, PT 7136 Possible to use one central control/payment system. Control data can be read and modified. For further details, see Central control via RS 232 interface, 090 4.4. 14.10.2005, DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
Descriptive Technical Documentation DTD no. 521-7135 090-4 4 Service 4.1 Fitting payment system on machine lid A Remove the machine lid. x Fig. 1 Warning! When drilling through the machine lid, take care to not drill into the surface on which it is resting! A Drill 4 fixing holes through the machine lid in accordance with the payment system template. x Fig. 2 A Place the plastic underlay on the machine lid.
DTD no. 521-7135 4.2 Descriptive Technical Documentation 090-5 Payment system (programme operation) x Note The instructions given in the documentation provided with the payment system must be followed. Fig. 3 A Open the pre-punched opening/s in the rear casing for the electrical connections as necessary. x Warning! Take care to lay wires such that they cannot be damaged by sharp edges. A Fit the appropriate through-feed parts on the wires. Secure the through-feeds on the rear casing.
Descriptive Technical Documentation DTD no. 521-7135 090-6 4.3 Payment system (timed operation) x Note The instructions given in the documentation provided with the payment system must be followed. Warning! The connection has been modified. Danger of short circuit. When a time payment system C 5003 is fitted, the connection from pin 7 to connection 2 on the payment system must be disconnected.
DTD no. 521-7135 Descriptive Technical Documentation 090-7 A Set the tumble dryer payment system programmable option to Timed operation. A PT 7135 C and PT 7136: For Service Dept. programming mode see Programming mode summary, 080 4.1. A PT 5135 C and PT 5136: For Service Dept. programming mode see Programming mode summary, 080 4.2. A Fit the payment system on the machine lid, see Fitting payment system on machine lid, 090 4.1. 4.
Descriptive Technical Documentation DTD no. 521-7135 090-8 x Fig. 5 Fig. 6 A Unscrew and remove the mains connection box lid. Loosen the cable strain relief. A Pass the data cable through the casing opening for the mains connection cable. Lay the data cable to the RS 232 interface on the power-programme module (ELP). A Connect the data cable plug to the RS 232 interface and secure it with the screws. A Secure the data cable in the strain relief together with the mains connection cable.
DTD no. 521-7135 Descriptive Technical Documentation 090-9 A At the payment system socket (X1/1), cut either through the wire bridge 1W14 between pins 1 and 2 or the wire bridge 2W14 between pins 3 and 5 as desired. Insulate the wire ends. A At the tumble dryer, set the payment system programmable option to RS 232, see Programming mode summary, 080 4.1. 14.10.2005, DE_en This information should not be duplicated or passed on without Miele approval. All rights reserved.
090-10 This information should not be duplicated or passed on without Miele approval. All rights reserved. Descriptive Technical Documentation DTD no. 521-7135 14.10.