Installation plan Washer PW 6137 D (Steam heated) en - US 12.15 M.-Nr.
M.-Nr.
PW 6137 D (measurements in inches) 3
5 3/4 5 1/8 4 5 3/4 5 3/4 5 1/8 23 5/8 4 6 3/4 5 3/4 2 1/4 6 3/4 57 1/8 57 1/8 57 1/8 57 1/8 PW 6137 D (measurements in inches) 4
16 3/8 32 3/4 2 1/8 1/2 16 3/8 32 3/4 2 1/8 51 1/8 39 3/8 53 1/8 51 1/8 31 1/2 3 1/2 3 1/2 35 7/8 53 1/8 4 1 1/8 1 1/8 49 1/4 49 1/4 PW 6137 D (measurements in inches) 37 3/8 1/2 5
14 1/8 28 1/4 32 7/8 35 3/8 53 1/8 18 5/8 30 3/4 35 3/4 32 7/8 35 3/8 31 1/2 2 1/2 35 3/4 53 1/8 31 1/2 30 3/4 18 5/8 11 3/4 5 5/8 49 1/4 49 1/4 PW 6137 D (measurements in inches) 14 1/8 28 1/4 1/2 6
PW 6137 D (measurements in millimeters) 7
PW 6137 D (measurements in millimeters) 8
PW 6137 D (measurements in millimeters) 9
PW 6137 D (measurements in millimeters) 10
Technical Datasheet Washer-extractor: Heating: Legend: PW 6137 Steam (D) Solid circle around symbol: Connection mandatory en - US Broken circle around symbol: Connection optional or as required Optional extras: UG/ UO BS DAV Miele base Concrete base UO 6013 (UO = Open base ) Height Width Depth 5 11/16“ 30 11/16“ 35 3/8“ 144 mm 780 mm 899 mm UG 6013 (UG = closed base) Height Width Depth 5 11/16“ 31 ½“ 35 13/16“ 144 mm 800 mm 909 mm UO 6013-30 (UO = Open base) Height Width Depth 11 13/16“ 3
Machine connections: Electrical connection 1. Standard voltage (as supplied) Frequency Rated load Fuse rating Connection cable, min. cross-section (Connection cable not included) V Hz kW A 4 x AWG 14 3 AC 208V 60 2.3 3 × 15 4 x 1.5 mm² 2. Standard voltage (convertible) Frequency Rated load Fuse rating Connection cable, min. cross-section (Connection cable not included) V Hz kW A 4 x AWG 14 3 AC 220-240V 60 2.3 3 × 15 4 x 1.
Cold water (soft water) Min. water pressure/flow pressure Max. water pressure/flow pressure Max. throughput Max. throughput (if hot or raw water supply is not available) 2 inlet hoses with ¾" threaded union (female) On-site connection thread 14.5 psi 145 psi 6.9 gal/min 11 gal/min 100 kPa 1000 kPa 26 l/min 42 l/min Inch Length of inlet hose 59 1/16“ ¾" garden hose thread, male 1500 mm Hourly water demand (average for 60°C cotton program) determined at cold, hot and raw water connection Approx. 27.
Fittings Without base Machine must be firmly anchored to the floor! Anchor fittings included: 2 × angle brackets (from shipping lock) 2 × bolts DIN 571 (Ø × length) 2 × rawl plugs (Ø × length) 5/16 x 3 1/8“ ½ x 2 3/8“ 8 x 80 mm 12 x 60 mm 5/16 x 3 1/8“ ½ x 2 3/8“ 8 x 80 mm 12 x 60 mm 5/16 x 3 1/8“ ½ x 2 3/8“ 8 x 80 mm 12 x 60 mm 31 5/8“ 39 9/16“ 49 3/16“ 31 ½“ 35 13/16“ 804 mm 1005 mm 1250 mm 800 mm 910 mm The floor must be solid and able to support the machine.