Technical information
Technical Information 
26
T1302, T1303, T1322, T1329ci, T1323c, 
T1403 and T1405 Clothes Dryers
1.2    Heater Element – Activation 
Table 030-2: Heater Element Activation 
2  Function 
2.1  Residual Moisture Sensor System 
The Electronic Residual Moisture Sensor system uses the amount 
of moisture in the laundry to determine how wet / dry the laundry is. 
2.1.1   Residual Moisture Sensing – Drum Assembly 
The contacts for the system are isolated as follows: 
 Contact 1 – Drum Body 
 Contact 2 – Drum Ribs 
The contacts connect to two slip rings on the outside of the drum. 
2.1.2   Residual Moisture Sensor – Brush Assembly 
The Brush Assembly is mounted on the right side top edge of the 
frame. The Sensor has two brushes that contact the slip rings on 
the outside of the drum. The signal is sent to the Electronic through 
connector JP1 (pins 1 and 2) on the Electronic. 
2.2  Drum Bearing 
The Rear Drum Bearing provides support for the rear of the drum. 
The bearing assembly is fitted to the rear panel of the appliance 
using a twist-lock design.  
Program  Option Selected Heater Element R1 Heater Element R2
Normal -  N  Y 
Normal Turbo  Y  Y 
Normal Full Load  Y  Y 
Normal Gentle  N  Y 