Technical information
Technical Information 
63
T1302, T1303, T1322, T1329ci, T1323c, 
T1403 and T1405 Clothes Dryers
3  Fault Repair 
3.1  Fault Summary 
1.  Turn on the appliance 
2.  Select a program. 
3.  Press Start. 
4.  Allow the appliance to operate for at least two minutes. 
5.  Observe the display for the following: 
 Table 060-1: Fault Summary 
Fault Signal 
Cause 
LED 
Buzzer 
(if turned 
on) 
Fault 
Code 
Check(s) 
Child Lock LED 
flashes 
– – 
Lock function activated. 
Turn off the Child Lock Feature (see 3.2) 
Empty out container 
LED lights 
(condenser dryers 
only) 
Intermittent – 
Condensate container float switch. 
Empty out condenser drawer. Check pump for correct 
operation. 
Rotary iron LED 
flashes (5 Hz) 
Intermittent F2 
Heater Bank NTC Temperature Sensor (2R30). 
Check the Temperature Sensor and circuit. 
Hand iron LED 
flashes (5 Hz) 
Intermittent
F4 
Drum Support housing NTC Temperature Sensor (1R30) 
Fault. 
Check the Temperature Sensor and circuit. 
Anti-crease/Finish 
LED lights 
Intermittent – 
No load in drum or no-load registered by the Residual 
moisture sensor. Ensure laundry is present. Check the 
Residual Moisture Sensor circuit. 
Anti-crease/Finish 
LED lights 
Intermittent F55 
Program time limit exceeded. Ensure the Heater Elements are 
operating. 
Anti-crease/Finish 
LED lights 
– F41 
Programming / Electronic fault. Check wiring and connectors. 
Replace the electronic. 