Technical information
Technical Information 
70
T1302, T1303, T1322, T1329ci, T1323c, 
T1403 and T1405 Clothes Dryers
TEST STEP 
Flashing 
Rhythm Of 
Drying LED 
SERVICE 
LEVEL 
Flashing 
Rhythm Of 
Buzzer LED 
SERVICE 
FUNCTION 
Long Short 
Function Tested/Machine 
Response 
– 
5 
Residual moisture sensing circuit, 
high resistance check. 
Ensure the clip leads or the wires 
used in the low resistance check 
are removed; and no laundry is 
present in the drum. 
The appliance will operate for 
about 30 seconds. When the 
appliance stops observe the 
Normal LED: 
- On Steady: System OK. 
- Flashing: System faulty. 
– 
6 
Buzzer test. 
Vented dryer: Constant tone. 
Condenser dryer: Intermittent 
tone. 
– 
7 
LED display test. 
Each individual segment of the 
display and the LEDs flash 
2 
Refer to the Test 
Step – Activation 
and Navigation.
– 
8 
Heating relay 1 and 2 and drive. 
Drum turns with reversing as 
follows: 10 minutes counter 
clockwise, 2.5second pause, 10 
seconds clockwise, 2.5 second 
pause, etc. 
Heating 2 comes on after 1 
second during counterclockwise 
rotation. 
Table 060-5: Service Mode (continued from Table 060-4) (continued on Table 060-6) 