Technical information
Technical Information 
71
T1302, T1303, T1322, T1329ci, T1323c, 
T1403 and T1405 Clothes Dryers
Table 060-6: Service Mode (continued from Table 060-5) 
TEST STEP 
Flashing Rhythm 
Of Drying LED 
SERVICE 
LEVEL 
Flashing 
Rhythm Of 
Buzzer 
LED 
SERVICE 
FUNCTION 
Long Short 
Function Tested/Machine Response 
– 
1 
Float Switch Test (condenser 
models). Buzzer operates when the 
float switch is activated. 
3 
Digital 
sensor test 
– 
2 
Door Switch Test - Buzzer operates 
when the door is closed. 
4 
Operating 
hours 
For 
1000s h
For 
100s h
Long flashing pulses for thousands, 
short flashing pulses for hundreds. 
(e.g. 12 x long + 6 x short = 12000 h + 