User guide

Exhaust ducting and
connections
A gap of
3
/
8
" (10 mm) must be
provided between the appliance
and the floor. This gap is necessary
for proper air flow and must not be
blocked by a toe-kick or thick piled
carpets.
Sufficient venting of the installation
site is essential for proper dryer
operation. Inadequate ventilation will
increase energy use and drying
times.
Do not install the dryer next to a
refrigerator. The heat emanating
from the dryer can affect the
thermostat of the refrigerator,
causing it to run continuously.
,
WARNING
Danger of toxic fumes.
The exhaust gases from the dryer
must only be vented outside the
building.
DO NOT terminate the exhaust
ducts in a chimney, fireplace
ducting, a combustion appliance
vent flue, or enclosed,
unventilated area such as attics,
garages, crawlspaces, walls,
ceilings or concealed space of a
building.
To reduce the risk of fire, only use
metal ductwork.
Ducting
18