Operating instructions/Installation instructions
Table Of Contents
- Contents
- Caring for the environment
- IMPORTANT SAFETY INSTRUCTIONS
- Operating the tumble dryer
- Energy-saving tips
- Functioning of the heat-pump dryer
- Initial set-up
- 1. Notes on correct laundry care
- 2. Selecting a program
- 3. Loading the tumble dryer
- 4. Selecting program settings
- 5. Starting a program
- 6. Program end – removing the laundry
- Program chart
- Extra options
- Changing the program sequence
- Condensed water container
- Fragrance flacon
- Cleaning and care
- Frequently Asked Questions
- The display indicates messages or faults
- Unsatisfactory drying results
- The drying cycle duration is very long
- General problems with the tumble dryer
- Replacing the plinth filter
- Reactivating the plinth filter
- Checking the heat exchanger unit
- Cleaning the lint filter in the condensed water container
- Replacing the blocked spray jet for the Steam Care program
- Bottom right grille
- Customer Service
- MIELE
- IMPORTANT SAFETY INSTRUCTIONS
- Installation
- Technical data
- Settings
IMPORTANT SAFETY INSTRUCTIONS
12
Heat-pump technology and refrigerant:
The heat pump in this tumble dryer uses a gaseous refrigerant which
is condensed by the compressor. The refrigerant, which is brought to
a higher temperature level and liquified by condensing, is led in a
closed circuit through the heat exchanger unit where heat exchange
with the circulating drying air takes place.
- The humming noises caused by the heat pump during the drying
process are normal. This does not impair the efficient functioning
of the dryer.
- The refrigerant is not flammable or explosive.
- This tumble dryer contains fluorinated greenhouse gases. Her-
metically sealed.
Designation of refrigerant: R134a
Amount of refrigerant: 16.6 oz (0.47) kg
Global warming potential of refrigerant: 1430 kg CO
2
e
Global warming potential of appliance: 672 kg CO
2
e
This product contains chemicals known to the state of California
to cause cancer or reproductive harm. For more information go to
www.P65Warnings.ca.gov.