Operating instructions
Electrical connection U.K.
All electrical work must be carried out
by a suitably qualified and competent
person, in strict accordance with na
-
tional and local safety regulations.
Ensure power is not supplied to the ma
-
chine while installation work is being
carried out.
The voltage, rated load and fuse rating
are given on the data plate. Please en
-
sure these match the site mains supply.
This washer-extractor is supplied as
standard for connection to :
– 230 - 240 V / 1N / 50 Hz
13 A fuse rating
with a cable and plug for connection
to a suitable switched socket.
Connection should be made via a fused
plug and suitable switched socket
which is easily accessible after installa-
tion.
For extra safety it is advisable to install
a residual current device (RCD), with a
trip current of 30 mA (in accordance
with DIN VDE 0664, VDE 0100 Section
739).
Do not connect via an extension lead.
Important
The wires in the mains lead are col
-
oured in accordance with the following
code:
Green/yellow = earth
Blue = neutral
Brown = live
Where it is necessary to change plugs,
if the colours of the wires in the mains
lead of this appliance do not corre
-
spond with the coloured markings iden
-
tifying the terminals of your plug, pro
-
ceed as follows:
–
The wire which is coloured green
and yellow must be connected to the
terminal in the plug which is marked
with the letter E or by the earth sym
-
bol z or coloured green, or green
and yellow.
–
The wire which is coloured blue must
be connected to the terminal in the
plug which is marked with the letter
N or coloured black.
– The wire which is coloured brown
must be connected to the terminal in
the plug which is marked with the let-
ter L or coloured red.
WARNING:
THIS APPLIANCE
MUST BE EARTHED
Installation