C-G48-NG(LP) 4.2、Information of Gas Supply and Burner The minimum supplied gas pressure regulator is factory set at 4”Natural Gas W.C, and 10”L.P. Gas W.C. The external thread of product’s intake-tube is 3/4 inches.
Model #of burners and control method C-G24-NG (LP) 2 pieces Independent control C-G36-NG (LP) 3 pieces Independent control C-G48-NG (LP) 4 pieces Independent control Gas Species Intake-tube pressure (in.W.C.) Per BTU B.T.U./h Total BTU B.T.U./h Nozzle No.5. Transport and Storage In the process of transportation, handle carefully and keep upright to prevent damage of the product packing. Wrapped equipment should not be in open air for a long time, and shall be placed in a well-ventilated and non-corrosive gases warehouse. When equipment needs temporary storage, waterproof measures should be taken. 6. Installation and Debugging Any erroneous installation, adjustment, refit, overhaul or maintenance may cause property damage or personal injury.
Adjustable stainless steel legs to make the equipment level, and get the same level with other series of the equipment; Please lift the equipment rather than drag if you need to move it; Supplied gas pressure regulator is factory set at 4”Natural Gas W.C, and 10”L.P. Gas W.
7. Safety Notices and Precautions Warning! For your safety, do not place petrol and other flammables nearby. Please keep clean and free of flammables surroundings. (Read ANSI Z83.14B, 1991 for reference) Warning! Any erroneous installation, adjustment and refit may cause property damage or personal injury and maintenance failure. Read the instructions carefully before installation and using. Warning! Operation instruction must be placed in a conspicuous location.
Before operating, make sure place the unit horizontally by adjusting bottom adjustable legs, and place the catch tray properly. The pilot light has been set at the factory. Each burner has a pilot light. 8.1、Lighting the pilot light Turn the control valve at the position of “0”(Fig.2), make sure all knobs are in the close state. Light and hold an ignition source at the pilots. The pilot light may not be lighted immediately, for existing gas in the pipe.
8.5、Exchange main fire nozzle to switch gas source Remove control panel, grill, the pilot light head, and bottom tightening screw of the end of burner (arc), take out burner, then remove main fire nozzle with proper open spanner, exchange nozzle of another gas source, then screw it (Fig.5). Reinstall burner, the pilot light head, grill and control panel in proper place. Caution: Each main fire nozzle of the burner has been installed before delivery, normal use without adjustment but only switching gas.
(4) no use for long time, spread cooking oil on grill after cleaning. Warning: Before cleaning, all control valves must be turned off.
10. Troubleshooting
Problems Possible causes Problem solving Not lighting 1.Insufficient gas pressure in pipe 1.Contact the local gas supply dept. 2.Nozzle occlusion 2.Dredge nozzle 1.Insufficient gas pressure in pipe 1.Contact the local gas supply dept. 2.The main occlusion 2.Dredge nozzle Ignite the pilot light but not the main fire Close gas and heard a sound of fire Yellow flame and black smoke fire nozzle 3.Gas control valves have problems 3.Change gas control valves 4.11. Spare Parts The use of parts provided by other companies, our company has the right not to provide warranty service; Order replacement parts from authorized representatives and after-sale service agency. Provide the model number, serial number and description when you order components. Fig.
Matters Component No. Dimensions Qty Code name (mm)/Model 21102001031 1 21102002028 Control panel 1 21102003028 2 3 4 21102001021 301140001 301081006 Catch tray Kirsite knob Galvanized American outside six corner with pad tapping 1 21202002002 bottom border package 605*185 C-G24-NG(LP) 905*185 C-G36-NG(LP) 1215*185 C-G48-NG(LP) 490*196*25 C-G24-NG(LP)\36NG(LP)\48-NG(LP) 2 C-G24-NG(LP) 3 C-G36-NG(LP) 4 C-G48-NG(LP) 34 21202001002 5 Remark 1 21202003002 ST4.10 11 12 13 14 15 301030001 Pilot light valve-single unit 2 3 C-G24-NG(LP) AP7-1 4 C-G48-NG(LP) 301060001 Needle type pressure joint 1 1/8"-27NPT C-G24-NG(LP)\36NG(LP)\48-NG(LP) 301060002 Needle type pressure joint screw arbor 1 M5*23 C-G24-NG(LP)\36NG(LP)\48-NG(LP) 21102001030 301170015 301060003 Air input pipe Nozzle stator Pilot light head 2 C-G24-NG(LP) 3 C-G36-NG(LP) 4 C-G48-NG(LP) 2 C-G24-NG(LP) 3 C-G36-NG(LP) 4 C-G48-NG(LP) 2 C-G24-NG(LP) 3 A73007/TiPφ 4.
Name Qty Model 20 301110001 Adjustable counter top steel legs 4 φ41.5*100 C-G24-NG(LP)\36NG(LP)\48-NG(LP) 12.
Intertek N IT E US LI S T E D SA C CM D CM A T I O N LI S T Conforms to ANSI STD Z83.11-2016 Certified to CSA STD 1.8-2016 Conforms to NSF/ANSI STD.4 Intertek 4003935 Our products have the advantages of good durability and low maintenance charge. But to update some components and necessary maintenance, can prolong life length of the products. Contact the dealer for assistance. In order to avoid confusion, please follow the format in figure 8 and table 4.